Permit: T11EL02100
Permit Details
Apply Date:
08/04/2011
Applicant:
EDDIE HERNANDEZ
Description:
RES: ELEC UPGRADE 200AMPS
Contractors:
- 2 ZONA ELECTRICAL SERVICES INC
Outstanding Activity Conditions
Permit Number - T11EL02100
Permit Status: Final
Permit Description: RES: ELEC UPGRADE 200AMPS
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/04/2011 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T11EL02100
Permit Description: RES: ELEC UPGRADE 200AMPS
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/24/2011 | TEP CLEARANCE - AM | DROBEY | Approved | |
| 09/07/2011 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1) CANNOT ENTER OR EXIT TOP END WALL PER MANUFACTURES INSTRUCTIONS 2) PROTECT CONDUCTORS 300.4 3) NEED ANIT OXIDE COMPOUND ON ALL ALUMINUM CONDUCTORS 110.3 4) CANNOT USE SHEET METAL THREAD SCREWS FOR GROUNDING 250.8 5) SEPERATE GROUNDS AND NEUTRALS AT SUB PANEL & PROVIDE A NEUTRAL 250.24 & 200.6 6) SECURE "SE" CABLE TO BOX 312.5 (C) 7) PROVIDE PHYSICAL PROTECTION FOR "SE" CABLE 8) MAINTAIN WORKING SPACE AT STORAGE PANEL 110.26 9) USE LISTED CONNECTOR FOR COPPER AND ALUMINUM |
| 09/07/2011 | ELECTRIC - SERVICE UPGRADE | RHOLLAND | Approved | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* |