Permit: T11EL02091
Permit Details
Apply Date:
08/03/2011
Applicant:
DAWN ZEMA
Description:
RECONNECT ELECTRIC; RES
Outstanding Activity Conditions
Permit Number - T11EL02091
Permit Status: Expired
Permit Description: RECONNECT ELECTRIC; RES
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/03/2011 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T11EL02091
Permite Description: RECONNECT ELECTRIC; RES
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/05/2011 | ELECTRIC - RECONNECT | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 08/05/2011 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED PROPER COVERS AT ALL EXTERIOR RECEPTS (GFCI) PROTECT 2) MISSING SMOKE DETECTORS IN BEDROOMS/HALLWAY 3) EXPOSED WIRES HALL 4) MISSING FACE PLATES THRU-OUT HOUSE 5) IF YOUR REMODELING NEED PERMITS FROM CITY 6) MAIN SERVICE HAS SEVERAL CODE VIOLATIONS (NEEDS TO BE UPGRADED) WITH CITY PERMITS 7) EXPOSED WIRES AT EXTERIOR/ROMEX NEEDS TO BE IN CONDUIT UNDER 8' 8) THUMB LATCH NEEDED AT EGRESS DOORS (NO KEYED ALLOWED) |