Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/19/2012 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* CALLED # NO ANSWER |
|
| 08/05/2011 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED PROPER COVERS AT ALL EXTERIOR RECEPTS (GFCI) PROTECT 2) MISSING SMOKE DETECTORS IN BEDROOMS/HALLWAY 3) EXPOSED WIRES HALL 4) MISSING FACE PLATES THRU-OUT HOUSE 5) IF YOUR REMODELING NEED PERMITS FROM CITY 6) MAIN SERVICE HAS SEVERAL CODE VIOLATIONS (NEEDS TO BE UPGRADED) WITH CITY PERMITS 7) EXPOSED WIRES AT EXTERIOR/ROMEX NEEDS TO BE IN CONDUIT UNDER 8' 8) THUMB LATCH NEEDED AT EGRESS DOORS (NO KEYED ALLOWED) |