Permit: T11EL00998
Permit Details
Apply Date:
04/06/2011
Applicant:
BRENT MCMILLAN
Description:
RECONNECT:ELECTRIC RES
Outstanding Activity Conditions
Permit Number - T11EL00998
Permit Status: Expired
Permit Description: RECONNECT:ELECTRIC RES
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/06/2011 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T11EL00998
Permite Description: RECONNECT:ELECTRIC RES
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/08/2011 | ELECTRIC - RECONNECT | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 04/08/2011 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CONDUCTOR AT PANEL WIRED WITHOUT BREAKER PROTECTION 2) SMOKE DETECTORS NEEDED IN ALL BEDROOMS AND ADJACENT HALL 3) QUICK RELEASES NEEDED FOR SECURITY BARS OVER BEDROOM EGRESS WINDOWS OR REMOVE THEM 4) OUTLET PLATE COVERS NEEDED ON OUTLETS 5) GFI PROTECT KITCHEN COUNTER RECEPTS 6) BACK PATIO APPEARS TO BE ENCLOSED TO LIVING SPACE WITHOUT PERMIT. ELECTRICAL OUTLETS MISSING TO CODE 7) ROOM AT BACK OF CARPORT NOT WIRED TO CODE 8) FIXTURE AT BACK CORNER OF HOUSE FALLING OFF OF WALL 9) BLANK OFF UNUSED KNOCKOUT HOLE AT BOTTOM OF PANEL 10) CODUCTORS DOUBLED UP ON BREAKERS AT PANEL |