Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/08/2011 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CONDUCTOR AT PANEL WIRED WITHOUT BREAKER PROTECTION 2) SMOKE DETECTORS NEEDED IN ALL BEDROOMS AND ADJACENT HALL 3) QUICK RELEASES NEEDED FOR SECURITY BARS OVER BEDROOM EGRESS WINDOWS OR REMOVE THEM 4) OUTLET PLATE COVERS NEEDED ON OUTLETS 5) GFI PROTECT KITCHEN COUNTER RECEPTS 6) BACK PATIO APPEARS TO BE ENCLOSED TO LIVING SPACE WITHOUT PERMIT. ELECTRICAL OUTLETS MISSING TO CODE 7) ROOM AT BACK OF CARPORT NOT WIRED TO CODE 8) FIXTURE AT BACK CORNER OF HOUSE FALLING OFF OF WALL 9) BLANK OFF UNUSED KNOCKOUT HOLE AT BOTTOM OF PANEL 10) CODUCTORS DOUBLED UP ON BREAKERS AT PANEL |