Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
COMMERCIAL OTHER
Address:
4863 S 12TH AV
Address NEW:
4863 S 12TH AV
Apply Date:
03/09/2011
Applicant:
ALEJANDRO ZUBIRI
Description:
ELEC RECONNECT COMMERCIAL RETAIL

Outstanding Activity Conditions

Permit Number - T11EL00685
Permit Status: Expired
Permit Description: ELEC RECONNECT COMMERCIAL RETAIL
Total Outstanding Activity Conditions - 1
Date Name
03/09/2011 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T11EL00685
Permite Description: ELEC RECONNECT COMMERCIAL RETAIL
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
03/14/2011 ELECTRIC - RECONNECT N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
03/14/2011 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BATHROOM RECEPTS TO BE GFCI PROTECTED
2) WATER HEATER NOT CORD AND PLUG APPLIANCE
3) EXPOSED CONDUCTORS BACKROOM
4) GROUNDED RECEPTS ON NON GROUNDED CIRCUITS
5) REMOVE DANGLING RECEPT FROM BELOW PANEL
6) BREAKER TO BE LISTED FOR USE BY MANUFACTURE
7) OLD DISCONNECT NOT FOR USE AS JUNCTION BOX-CONDUCTORS DETERIORATED IN BOX
8) NO PANEL LABELING
9) NO LAST WRITE UP ON SITE

Documents

File Name Document Type  
None DOCUMENTS VIEW