Permit: T11EL00520
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
1733 S ROSEMONT AV
Address NEW:
1733 S ROSEMONT AV
Apply Date:
02/24/2011
Applicant:
CENTURY 21 DM REALTY/ANTHONY RIVAS
Description:
RECONNECT:ELECTRIC:SFR
Outstanding Activity Conditions
Permit Number - T11EL00520
Permit Status: Expired
Permit Description: RECONNECT:ELECTRIC:SFR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/24/2011 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T11EL00520
Permite Description: RECONNECT:ELECTRIC:SFR
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/02/2011 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) IS ADDITION AT REAR PERMITTED ? HAS SEVERAL VIOLATIONS 2) REAR ADDITION HAS EXPOSED WIRING AND NO COMBUSTION RELIEF FOR GAS APPLIANCES 3) ALL EXTERIOR RECEPTS AT GRADE NEED TO BE GFCI PROTECTED WITH COVERS 4) NEED GFCI PROTECTION ON ALL BATH/KITCHEN COUNTER RECEPTS 5) NEED SMOKE DETECTORS IN ALL SLEEPING ROOMS AND HALLWAY 6) MIS-MATCHED 2 & 3 PRONG OUTLETS INSTALLED. IF BLDG HAS NO GROUNDING SYSTEM PROVIDE GFCI PROTECTION OR REPLACE (3) PRONG RECEPTS WITH (2) PRONG 7) MISSING FACE PLATES THROUGHOUT 8) BLDG ELECTRIC TO BE SAFE TO RELEASE |
| 04/07/2011 | ELECTRIC - RECONNECT | N/A | Partial Approval | IVRS - Inspection :* 1) ADDITION AT REAR NEEDS TO BE PERMITTED OR REMOVED. SEVERAL CODE ISSUES 2) BEDROOM AT REAR WHERE ADDITION HAS BEEN BUILT HAS NO EGRESS OR INGRESS 3) CAN CHANGE DOWNTOWN TO OFFICE/DEN |
Completed Inspections
Permit Status: Expired
Permit Number: T11EL00520
Permit Description: RECONNECT:ELECTRIC:SFR
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/08/2011 | TEP CLEARANCE - AM | JWEATHER | Approved | RECN CLEARED PER D. WALKER |