Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/02/2011 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) IS ADDITION AT REAR PERMITTED ? HAS SEVERAL VIOLATIONS 2) REAR ADDITION HAS EXPOSED WIRING AND NO COMBUSTION RELIEF FOR GAS APPLIANCES 3) ALL EXTERIOR RECEPTS AT GRADE NEED TO BE GFCI PROTECTED WITH COVERS 4) NEED GFCI PROTECTION ON ALL BATH/KITCHEN COUNTER RECEPTS 5) NEED SMOKE DETECTORS IN ALL SLEEPING ROOMS AND HALLWAY 6) MIS-MATCHED 2 & 3 PRONG OUTLETS INSTALLED. IF BLDG HAS NO GROUNDING SYSTEM PROVIDE GFCI PROTECTION OR REPLACE (3) PRONG RECEPTS WITH (2) PRONG 7) MISSING FACE PLATES THROUGHOUT 8) BLDG ELECTRIC TO BE SAFE TO RELEASE |