Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
4043 E 26TH ST
Address NEW:
4043 E 26TH ST
Apply Date:
10/27/2011
Applicant:
MICHAEL MUSSACK
Description:
ELECTRIC RECONNECT:RES

Permit Reviews

Permit Number - T11CM03396
Permit Status: Final
Permit Description: ELECTRIC RECONNECT:RES
Start Date Submittal Complete Date Status  
10/27/2011 OTHER 11/10/2011 COMPLETED Review Details
11/10/2011 REVISION - - 1ST 11/10/2011 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T11CM03396
Permit Status: Final
Permit Description: ELECTRIC RECONNECT:RES
Total Outstanding Activity Conditions - 1
Date Name
10/27/2011 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T11CM03396
Permit Description: ELECTRIC RECONNECT:RES
Total Completed Inspections - 5
Date Description Inspector Results Comments
11/23/2011 ELECTRIC - RECONNECT DWALKER Approved 1. SUBPANEL REQUIRES (4) WIRE PULL - NEED EQUIPMENT GROUNDING CONDUCTOR.
2. ALL EQUIPMENT GROUNDS & NEUTRALS NEED TO BE SEPARATED AT SUB PANEL BUS BAR
3. GROUNDING ELECTRODE CONDUCTOR NEEDS TO HIT GROUND RODS FIRST, THEN GAS LINE BOND
4. SECURE GROUND TO WALL UNDER PANEL
5. PUT ADDRESS ON PANEL
02/02/2012 ELECTRIC - SERVICE UPGRADE DSANTACR Approved
02/02/2012 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
02/02/2012 TEP CLEARANCE - AM JWEATHER Approved RECN CLEARED PER D. SANTACRUZ
02/06/2012 PERMIT FINALED JWEATHER Approved