Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
COMMERCIAL ALTERATION
Address:
6107 S 6TH AV
Address NEW:
6107 S 6TH AV
Apply Date:
01/27/2011
Applicant:
N/A
Description:
TI:BARBER SHOP
Contractors:
  • ARIZONA HARD ROCK CONSTRUCTION AND DEVELOPMENT

Permit Reviews

Permit Number - T11CM00230
Permit Status: Expired
Permit Description: TI:BARBER SHOP
Start Date Submittal Complete Date Status  
01/27/2011 COMMERCIAL - TI 02/03/2011 COMPLETED Review Details
11/15/2011 REVISION - - 1ST 11/16/2011 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T11CM00230
Permit Status: Expired
Permit Description: TI:BARBER SHOP
Total Outstanding Activity Conditions - 1
Date Name
01/27/2011 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T11CM00230
Permite Description: TI:BARBER SHOP
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
ELECTRIC - INTERMEDIATE N/A Not Inspected
ELECTRIC - ABOVE CEILING N/A Not Inspected
PLUMBING - INTERMEDIATE N/A Not Inspected
PLUMBING - GAS PRESSURE TEST N/A Not Inspected
11/10/2011 PLUMBING - PROGRESS N/A Not ready for Inspection 1) LAST KNOWN OCCUPANCY OF THIS BLDG WAS A SEAFOOD RESTAURANT. NOT IT IS A COMPLETED BARBER SHOP. PROVIDE DEMO PLAN SHOWING HOW FLOOR SINKS, FLOOR DRAINS, GREASE WASTE AND WATER PIPING DISTRIBUTION AND DWV ISOMETRIC
2) PLAN SHOWS 2 LAVS CHANGING TO SHAMPOO BOWLS. SHOW HOW SECOND HISTORY WAS CAPPED OFF. ONE SHAMPOO BOWL WAS MOVED TO WALL NEXT TO WATER HEATER. SHOW HOW THE PLUMBING WAS CONNECTED BELOW GRADE AND TEST
3) RPPBP AT WATER SERVICE MAKES THIS A CLOSED SYSTEM, REQUIRE EXPANSION TANK AND RPPBP CERT
4) WILL REQUIRE STERILIZATION AND CLEAN BACTERIA REPORT

Completed Inspections

Permit Status: Expired
Permit Number: T11CM00230
Permit Description: TI:BARBER SHOP
Total Completed Inspections - 11
Date Description Inspector Results Comments
11/02/2011 RIGHT OF WAY - FINAL LHANLY Approved
11/02/2011 NPPO - FINAL LHANLY Approved
11/02/2011 SIGN - FINAL LHANLY Approved
11/02/2011 LANDSCAPE - FINAL LHANLY Approved
11/02/2011 ENGINEERING - FINAL LHANLY Approved
11/08/2011 FIRE - FINAL WMOTTO Approved
11/09/2011 ELECTRIC - FINAL RMORENO Approved IVRS - Inspection :*
11/09/2011 ELECTRIC - RECONNECT RMORENO Approved IVRS - Inspection :*
11/10/2011 TEP CLEARANCE - AM JWEATHER Approved RECN CLEARED PER R. MORENO
11/28/2011 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
1) PER TUCSON POLICY, HELD OVER INSPECTIONS ARE TO BE PERFORMED FIRST ON THE FOLLOWING WORK DAY. 8:30 AM DOOR IS LOCKED
2) PLEASE CALL ME DIRECTLY, AT YOUR EARLIEST CONVENIENCE AND I WILL TRY TO COME BACK TODAY TO HELP YOU THRU THIS FINAL STEP
REINSPECTED 9:00 AM:
1) CORRECTIONS MADE OK
3) OWNER TO MODIFY LAV DRAIN
11/28/2011 BUILDING - FINAL RMYERS Approved IVRS - Inspection :*

Documents

File Name Document Type  
001_PLOT PLAN.TIF CONSTRPLANS VIEW
002_FLOOR & DEMO.TIF CONSTRPLANS VIEW
003_ELEC & MECH.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW