Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T11CM00230

Parcel: 138111720


Addresses:

6107 S 6TH AV

Inspection Status: Not ready for Inspection

Inspection History: PLUMBING - PROGRESS

Date Description Inspector Results Comments
11/10/2011 PLUMBING - PROGRESS Not ready for Inspection 1) LAST KNOWN OCCUPANCY OF THIS BLDG WAS A SEAFOOD RESTAURANT. NOT IT IS A COMPLETED BARBER SHOP. PROVIDE DEMO PLAN SHOWING HOW FLOOR SINKS, FLOOR DRAINS, GREASE WASTE AND WATER PIPING DISTRIBUTION AND DWV ISOMETRIC
2) PLAN SHOWS 2 LAVS CHANGING TO SHAMPOO BOWLS. SHOW HOW SECOND HISTORY WAS CAPPED OFF. ONE SHAMPOO BOWL WAS MOVED TO WALL NEXT TO WATER HEATER. SHOW HOW THE PLUMBING WAS CONNECTED BELOW GRADE AND TEST
3) RPPBP AT WATER SERVICE MAKES THIS A CLOSED SYSTEM, REQUIRE EXPANSION TANK AND RPPBP CERT
4) WILL REQUIRE STERILIZATION AND CLEAN BACTERIA REPORT