Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY COMPLIANCE
Address:
2228 E 6TH ST
Address NEW:
2228 E 6TH ST
Apply Date:
01/20/2011
Applicant:
N/A
Description:
COMPLIANCE:ADDITION:UTILITY ROOM:T10DV07859

Permit Reviews

Permit Number - T11CM00170
Permit Status: Expired
Permit Description: COMPLIANCE:ADDITION:UTILITY ROOM:T10DV07859
Start Date Submittal Complete Date Status  
01/20/2011 RESIDENTIAL - BLDG/ZONING-WALKTHRU 03/01/2011 COMPLETED Review Details
03/01/2011 OTHER 03/09/2011 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T11CM00170
Permit Status: Expired
Permit Description: COMPLIANCE:ADDITION:UTILITY ROOM:T10DV07859
Total Outstanding Activity Conditions - 1
Date Name
01/20/2011 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T11CM00170
Permite Description: COMPLIANCE:ADDITION:UTILITY ROOM:T10DV07859
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
BUILDING - PROGRESS N/A Not Inspected
03/25/2011 BUILDING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED HEADER AT WINDOW
2) NEED ANCHOR BOLTS ADDED TO SOLE PLATES
3) NEED WATER HAMMERS ON HOT/COLD WASHING MACHINE
4) NO P-TRAP AT LAUNDRY STAND PIPE (ADD ONE)
5) B-VENT NEEDS MINIMUM 1" CLEARANCE TO COMBUSTIBLES
6) FILL ALL HOLES IN JOIST HANGERS AND H2.5 CONNECTIONS
7) PROVIDE COMBUSTION VENTS FOR GAS WATER HEATER
8) EXTEND B-VENT ABOVE ROOF MINIMUM 2' FT
9) EXTERIOR SIDING LOOSE NEEDS TO BE NAILED CODE MINIMUM 6" EDGES 12" FIELD

Documents

File Name Document Type  
001_1 OF 3.TIF CONSTRPLANS VIEW
002_2 OF 3.TIF CONSTRPLANS VIEW
003_3 OF 3.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW