Permit: T11CM00170
Permit Details
Apply Date:
01/20/2011
Applicant:
N/A
Description:
COMPLIANCE:ADDITION:UTILITY ROOM:T10DV07859
Permit Reviews
Permit Number - T11CM00170
Permit Status: Expired
Permit Description: COMPLIANCE:ADDITION:UTILITY ROOM:T10DV07859
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/20/2011 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 03/01/2011 | COMPLETED |
| 03/01/2011 | OTHER | 03/09/2011 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T11CM00170
Permit Status: Expired
Permit Description: COMPLIANCE:ADDITION:UTILITY ROOM:T10DV07859
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/20/2011 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T11CM00170
Permite Description: COMPLIANCE:ADDITION:UTILITY ROOM:T10DV07859
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| BUILDING - PROGRESS | N/A | Not Inspected | ||
| 03/25/2011 | BUILDING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED HEADER AT WINDOW 2) NEED ANCHOR BOLTS ADDED TO SOLE PLATES 3) NEED WATER HAMMERS ON HOT/COLD WASHING MACHINE 4) NO P-TRAP AT LAUNDRY STAND PIPE (ADD ONE) 5) B-VENT NEEDS MINIMUM 1" CLEARANCE TO COMBUSTIBLES 6) FILL ALL HOLES IN JOIST HANGERS AND H2.5 CONNECTIONS 7) PROVIDE COMBUSTION VENTS FOR GAS WATER HEATER 8) EXTEND B-VENT ABOVE ROOF MINIMUM 2' FT 9) EXTERIOR SIDING LOOSE NEEDS TO BE NAILED CODE MINIMUM 6" EDGES 12" FIELD |