Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Apply Date:
01/05/2010
Applicant:
JAIRO GARCIA
Description:
RECONNECT:GAS LINE:SFR

Outstanding Activity Conditions

Permit Number - T10PL00005
Permit Status: Expired
Permit Description: RECONNECT:GAS LINE:SFR
Total Outstanding Activity Conditions - 1
Date Name
01/05/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T10PL00005
Permite Description: RECONNECT:GAS LINE:SFR
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
01/22/2010 PLUMBING - GAS PRESSURE TEST N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TEST TO HOLD MINIMUM 10 PSI WITH NO LOSS OF PRESSURE FOR 15 MINUTES
2) NO UNION CAN BE INSTALLED UNDERGROUND
3) PROVIDE APPROVED GAS SHUT OFF VALVES FOR ALL APPLIANCES
4) VENT ON WATER HEATER TO BE INSTALLED CORRECTLY WITH APPROVED VENT MATERIAL TERMINATING CORRECTLY
5) WATER HEATER TEMPERATURE AND PRESSURE RELIEF TO BE FUNCTIONAL AND GRAVITY DRAIN TO DAYLIGHT WITH APPROVED PIPING (NO FLEX) TERMINATING AT 90 DEGREE DOWN ON EXTERIOR 6" TO 24" FROM FINISH GRADE
6) GAS PIPING IN A WOOD BURNING FIREPLACE SHALL BE VALUED ON EXTERIOR OF HEARTH IN SAME ROOM AS FIREPLACE WITHIN 6 FEET OF HEARTH (NO LIVE GAS PIPING INSIDE HEARTH)
7) WATER HEATER TO BE INSTALLED IN DRIP PAN ON FLOOR NOT ON WOOD BLOCKS
8) THIS IS NOT A GAS RECONNECT, PROVIDE A CITY APPROVED GAS ISOMETRIC PLAN WITH BTU, SIZE OF PIPING AND DISTANCES OF PIPE RUNS. IT APPEARS YOUR PIPING IS UNDER SIZED
9) HAVE A LADDER ON SITE TO INSPECT ALL VENT TERMINATIONS
10) PROVIDE BONDING OF GAS PIPING
11) LIST NOT COMPLETE
01/22/2010 PLUMBING - GAS RECONNECT N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
01/22/2010 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*