Permit: T10ME00602
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
576 S STEPHANIE LP
Address NEW:
576 S STEPHANIE LP
Apply Date:
09/28/2010
Applicant:
QUINN KRISTI
Description:
REMOVE AND REPLACE EXSISTING 4 TON SPLIT SYSTEM WITH NEW 4 TON SPLIT SYSTEM
Contractors:
- RUSSET SERVICE CORPORATION *APA*
Outstanding Activity Conditions
Permit Number - T10ME00602
Permit Status: Expired
Permit Description: REMOVE AND REPLACE EXSISTING 4
TON SPLIT SYSTEM WITH NEW 4
TON SPLIT SYSTEM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/28/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T10ME00602
Permite Description: REMOVE AND REPLACE EXSISTING 4
TON SPLIT SYSTEM WITH NEW 4
TON SPLIT SYSTEM
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/29/2010 | MECHANICAL - INTERMEDIATE | N/A | Not ready for Inspection | IVRS - Inspection :* |
| 12/30/2010 | MECHANICAL - FINAL | N/A | Partial Approval | IVRS - Inspection :* 1) ALL JOINTS TO BE PRIMED, PRIMER IS TO BE PURPLE IN COLOR 2) ALL DUCT WITHIN MECH-CLOSET IS TO BE INSULATED 3) CORD CONNECTOR AT INDOOR UNIT IS LOOSE 4) PROVIDE TIGHT FITTING JOINTS ON FLUE PIPING, MINIMUM 1" INSERTION AT ALL JOINTS, B-VENT THRU WALL NOT PROPERLY INSTALLED 5) PROVIDE SERVICE OUTLET ON ROOF WITHIN 25' OF UNIT |