Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Closed
Type:
SINGLE FAMILY OTHER
Address NEW:
1255 E PASEO ALEGRE
Apply Date:
09/17/2010
Applicant:
READ CHRISTOPHER F & GRAHAM HEATHER S JT/RS
Description:
REPLACEMENT: GAS PACK AC/HEAT
Contractors:
  • SOUTHERN ARIZONA RAIN GUTTERS

Permit Reviews

Permit Number - T10ME00589
Permit Status: Closed
Permit Description: REPLACEMENT: GAS PACK AC/HEAT
Start Date Submittal Complete Date Status  
09/17/2010 MECHANICAL 09/17/2010 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T10ME00589
Permit Status: Closed
Permit Description: REPLACEMENT: GAS PACK AC/HEAT
Total Outstanding Activity Conditions - 1
Date Name
09/17/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Closed
Permit Number: T10ME00589
Permite Description: REPLACEMENT: GAS PACK AC/HEAT
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
09/20/2010 MECHANICAL - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PVC TO TERMINATE 6" ABOVE GRADE
2) PVC TO BE U.V. COATED
3) CONDENSATE TRAP INSTALLED WRONG, VENT ON WORNG SIDE
4) BLACK WIRE NOT TO BE USED AS GROUND
5) ALL PVC JOINTS ARE TO BE PRIMED, ALL PRIMER IS TO BE PURPLE IN COLOR
6) PROVIDE SERVICE OUTLET WITHIN 25' OF UNIT AT SAME LEVEL

Documents

File Name Document Type  
None DOCUMENTS VIEW