Description:
Replace (2) 5 ton gas package units. Like for like. Roof mounted.
Contractors:
  • RITEWAY VENTILATING *C*

Outstanding Activity Conditions

Permit Number - T10ME00290
Permit Status: Expired
Permit Description: Replace (2) 5 ton gas package units. Like for like. Roof mounted.
Total Outstanding Activity Conditions - 1
Date Name
05/17/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T10ME00290
Permite Description: Replace (2) 5 ton gas package units. Like for like. Roof mounted.
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
06/01/2010 MECHANICAL - INTERMEDIATE N/A Partial Approval IVRS - Inspection :*
06/01/2010 MECHANICAL - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) VERIFY 2" LINER IN NEW DUCT ON ROOF
2) PROVIDE FILTERED O.S.A. ON UNITS
3) CONDENSATE MUST TERMINATE AT AN APPROVED LOCATION
4) WHEN TIE IN TO CONDENSATE LINES TOGETHER THE MIN. PIPE SIZE IS 1"
5) BLOCKING FOR P.V.C. PIPING NOT TO EXCEED 48"
6) PROVIDE GAS PRESSURE TEST OR LEAK DETECTING BUBBLES FOR NEW GAS PIPING ON ROOF