Permit: T10EL02843
Permit Details
Apply Date:
12/22/2010
Applicant:
THE SHYANN KINDNESS PROJECT
Description:
RECONNECT:ELECTRIC:THE SHYANN KINDNESS PROJECT
Outstanding Activity Conditions
Permit Number - T10EL02843
Permit Status: Expired
Permit Description: RECONNECT:ELECTRIC:THE SHYANN KINDNESS PROJECT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/22/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T10EL02843
Permite Description: RECONNECT:ELECTRIC:THE SHYANN KINDNESS PROJECT
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/27/2010 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CANNOT DBL LUG CONDUCTORS IN SERVICE DISCONNECT 2) UNSAFE WIRING AT 2727 IN BACK AND IS ATTACHED TO 2525 METAL SHADE STRUCTURE 3) EXPOSED WIRING AT OUTSIDE FRONT WHERE SIGN USED TO BE 4) SUPPORT CONDUITS, PLUG HOLES IN RECEPT BOXES INSIDE BLDG, ALSO RECEPTS NOT INSTALLED IN BOXES (HANGING OUT ?) 5) EXPOSED WIRING INSIDE BACK AREA BY PANEL, FLOURESCENT FIXTURE MISSING COVER 6) CUT OFF EXTENSION CORDS CANNOT BE USED AS WIRING METHOD OUTSIDE BACK OF BLDG, ALSO RECEPTS MISSING COVERS 7) HAVE ELECTRICIAN CHECK OUT ROOF AND REPAIR ELECTRIC, HAVE LADDER ON SITE NEXT INSPECTION 8) USE LICENSED OR QUALIFIED ELECTRICIAN TO DO WORK |
Completed Inspections
Permit Status: Expired
Permit Number: T10EL02843
Permit Description: RECONNECT:ELECTRIC:THE SHYANN KINDNESS PROJECT
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/27/2010 | ELECTRIC - RECONNECT | DSANTACR | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 01/07/2011 | TEP CLEARANCE - AM | JWEATHER | Approved | RECN CLEARED PER D. SANTACRUZ |