Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
2102 S FARWELL AV
Apply Date:
12/06/2010
Applicant:
JUAN RODRIGUEZ
Description:
RES: ELEC UPGRADE 200AMPS

Outstanding Activity Conditions

Permit Number - T10EL02734
Permit Status: Expired
Permit Description: RES: ELEC UPGRADE 200AMPS
Total Outstanding Activity Conditions - 1
Date Name
12/06/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T10EL02734
Permite Description: RES: ELEC UPGRADE 200AMPS
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
ELECTRIC - FINAL N/A Not Inspected
12/14/2010 ELECTRIC - SERVICE UPGRADE N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED PROPER WORKING CLEARANCE IN FRONT OF PANEL MIN 36" DEEP
2) GROUND RODS TO BE MINIMUM 6' APART
3) NEED MINIMUM 24" ON NEUTRAL OUT OF WEATHERHEAD
4) BOND WATER PIPING
5) LUGS ON GROUND ROD ONLY LISTED FOR 1 WIRE TERMINATION
6) VERIFY WITH TEP LOCATION OF NEW SERVICE IS ACCEPTABLE

Completed Inspections

Permit Status: Expired
Permit Number: T10EL02734
Permit Description: RES: ELEC UPGRADE 200AMPS
Total Completed Inspections - 1
Date Description Inspector Results Comments
01/06/2011 TEP CLEARANCE - AM JWEATHER Approved INCR CLEARED PER R. JIROUDEK

Documents

File Name Document Type  
None DOCUMENTS VIEW