Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
MULTI FAMILY OTHER
Address NEW:
4709 S 7TH AV #02
Apply Date:
11/22/2010
Applicant:
ALEJANDRA BUEHLER
Description:
RECONNECT:ELECTRIC:APT

Outstanding Activity Conditions

Permit Number - T10EL02646
Permit Status: Expired
Permit Description: RECONNECT:ELECTRIC:APT
Total Outstanding Activity Conditions - 1
Date Name
11/22/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T10EL02646
Permite Description: RECONNECT:ELECTRIC:APT
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
11/24/2010 ELECTRIC - RECONNECT N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
11/24/2010 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REMOVE ZIP CORD WIRING FROM FRONT PORCH LIGHT. ALSO FIXTURE BROKEN
2) EXPOSED/OPEN CONDUCTORS IN FRONT WALL AT SWITCH
3) KITCHEN RECEPT TO BE GFI PROTECTED-FILL UNUSED OPENING IN BOX
4) REATTACH BOX IN CLOSET AND PROTECT BULB
5) GROUNDED RECEPTS ON NON GROUNED CIRCUITS
6) SUPPORT CONDUIT BEDROOMS
7) REPLACE COVERS AT MAIN BREAKER
8) MISSING DEAD FRONT COVER PANEL
9) JUNCTION BOX/OLD PANEL ABOVE PANEL NOT LEGAL PER CODE
10) BOND JUMPER CANNOT BE WHITE 200.6
11) WROUGHT IRON WINDOWS NEED QUICK RELEASE
12) SMOKE DETECTORS 3' FROM DUCTS AND 7-9" DOWN

Documents

File Name Document Type  
None DOCUMENTS VIEW