Permit: T10EL02201
Permit Details
Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
3996 S EVERGREEN AV
Address NEW:
3996 S EVERGREEN AV
Apply Date:
09/22/2010
Applicant:
KENN RUST
Description:
RECONNECT ELECTRIC; RES
Outstanding Activity Conditions
Permit Number - T10EL02201
Permit Status: Final
Permit Description: RECONNECT ELECTRIC; RES
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/22/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T10EL02201
Permit Description: RECONNECT ELECTRIC; RES
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/09/2010 | ELECTRIC - FINAL | WLAHR | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) GFI PROTECT BATHROOM OUTLET ON FIXTURE 2) SMOKE DETECTORS NEEDED IN BEDROOMS 3) SMOKE DETECTOR IN HALLWAY NEEDS TO BE WORKING 4) ILLEGAL ADDITION AT BACK ENCLOSED EGRESS FOR MASTER BEDROOM 5) NEED ACCESS TO UTILITY ROOM OFF BACK 6) BLANK OFF OPEN SPACES AT PANEL 7) GFI PROTECT ALL COUNTER RECEPTS IN KITCHEN 8) LABEL ALL CIRCUITS AT PANEL 9) BLANK UNUSED KNOCKOUTS AT PANEL 10) GFI PROTECT EXTERIOR OUTLETS 11) DISHWASHER NEEDS TO BE ON DEDICATED CIRCUIT NOT INTO COUNTER RECEPTS 12) REMOVE UNUSED CONDCUCTOR IN ADDITION AT REAR |
| 12/09/2010 | ELECTRIC - RECONNECT | WLAHR | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 02/25/2011 | TEP CLEARANCE - AM | JWEATHER | Approved | RECN CLEARED PER W. LAHR |
| 02/25/2011 | PERMIT FINALED | JWEATHER | Approved |