Permit: T10EL00486
Permit Details
Apply Date:
03/04/2010
Applicant:
RUTH ROUBAL *C
Description:
ELEC RECONNECT (APA)
Outstanding Activity Conditions
Permit Number - T10EL00486
Permit Status: Expired
Permit Description: ELEC RECONNECT (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/04/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T10EL00486
Permite Description: ELEC RECONNECT (APA)
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/08/2010 | ELECTRIC - RECONNECT | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 03/08/2010 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) KITCHEN COUNTER RECEPTS TO BE GFI PROTECTED 2) OUTDOOR RECEPTS TO BE GFI PROTECTED 3) BATHROOM RECEPTS TO BE GFI PROTECTED 4) HAVE EXPOSED WIRING AT DBL OVEN LOCATION 5) HAVE GROUNDING TYPE RECEPTS ON UNGROUNDED 2 WIRE SYSTEM 6) MISSING WALL PLATES 7) HAVE BROKEN RECEPTS 8) WIRE HANGING OUT OF CEILING MSTR BEDROOM 9) NON CODE COMPLIANT TAPS AT SERVICE 10) EQUIPMENT AND WIRING TO SPA/HOT TUB EXPOSED TO WEATHER 11) BLANK OPEN BREAKER POSITIONS IN PANEL 12) CLOSET LIGHTS TO BE 100 PERCENT ENCLOSED 13) HAVE QUALIFIED ELECTRICAL CONTRACTOR MAKE REPAIRS AND GO THRU ENTIRE HOME & CHECK WIRING SYSTEM |