Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
5212 E 3RD ST
Address NEW:
5212 E 3RD ST
Apply Date:
03/04/2010
Applicant:
RUTH ROUBAL *C
Description:
ELEC RECONNECT (APA)

Outstanding Activity Conditions

Permit Number - T10EL00486
Permit Status: Expired
Permit Description: ELEC RECONNECT (APA)
Total Outstanding Activity Conditions - 1
Date Name
03/04/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T10EL00486
Permite Description: ELEC RECONNECT (APA)
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
03/08/2010 ELECTRIC - RECONNECT N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
03/08/2010 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) KITCHEN COUNTER RECEPTS TO BE GFI PROTECTED
2) OUTDOOR RECEPTS TO BE GFI PROTECTED
3) BATHROOM RECEPTS TO BE GFI PROTECTED
4) HAVE EXPOSED WIRING AT DBL OVEN LOCATION
5) HAVE GROUNDING TYPE RECEPTS ON UNGROUNDED 2 WIRE SYSTEM
6) MISSING WALL PLATES
7) HAVE BROKEN RECEPTS
8) WIRE HANGING OUT OF CEILING MSTR BEDROOM
9) NON CODE COMPLIANT TAPS AT SERVICE
10) EQUIPMENT AND WIRING TO SPA/HOT TUB EXPOSED TO WEATHER
11) BLANK OPEN BREAKER POSITIONS IN PANEL
12) CLOSET LIGHTS TO BE 100 PERCENT ENCLOSED
13) HAVE QUALIFIED ELECTRICAL CONTRACTOR MAKE REPAIRS AND GO THRU ENTIRE HOME & CHECK WIRING SYSTEM