Permit Details

Status:
Closed
Type:
SINGLE FAMILY OTHER
Apply Date:
01/28/2010
Applicant:
LOUIS BLASS
Description:
RECONNECT:ELECTRIC RES

Outstanding Activity Conditions

Permit Number - T10EL00189
Permit Status: Closed
Permit Description: RECONNECT:ELECTRIC RES
Total Outstanding Activity Conditions - 1
Date Name
01/28/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Closed
Permit Number: T10EL00189
Permite Description: RECONNECT:ELECTRIC RES
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
01/29/2010 ELECTRIC - RECONNECT N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
01/29/2010 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) KITCHEN COUNTER RECEPTS NEED TO BE GFI PROTECTED
2) SMOKE DETECTORS IN NORTH BEDROOMS TO CLOSE TO A/C REGISTERS, SHOULD BE AT LEAST 3' AWAY
3) SERVICE EQUIPMENT OUT DATED AND NOT TO CODE-EXPOSED CABLES, DBL LUGGING ON LOAD AND LINE SIDE OF MAIN SERVICE DISCONNECT. EQUIPMENT NOT RATED FOR OUTDOOR USE
4) RECEPTS ON BACK WALL AND STORAGE NOT TO CODE
5) SERVICE NOT GROUNDED
6) UPGRADE SERVICE AND OTHER CORRECTIONS AND RECALL INSPECTION, OBTAIN SERVICE UPGRADE PERMIT OR ADD TO THIS ONE
7) USE QUALIFIED OR LICENSED ELECTRICIAN