Permit: T10CM03318
Permit Details
Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address:
5425 S GREENWAY DR
Address NEW:
5425 S GREENWAY DR
Apply Date:
11/29/2010
Applicant:
N/A
Description:
INSTALL:SOLAR ELECTRIC ROOF MOUNT
Contractors:
- SIMPLY SOLAR OF ARIZONA L L C
Permit Reviews
Permit Number - T10CM03318
Permit Status: Expired
Permit Description: INSTALL:SOLAR ELECTRIC ROOF MOUNT
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/29/2010 | RESIDENTIAL - BLDG/WWM | 12/08/2010 | ACTIVE |
| 11/29/2010 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 11/29/2010 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T10CM03318
Permit Status: Expired
Permit Description: INSTALL:SOLAR ELECTRIC ROOF MOUNT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/29/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T10CM03318
Permite Description: INSTALL:SOLAR ELECTRIC ROOF MOUNT
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/22/2010 | BUILDING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
Completed Inspections
Permit Status: Expired
Permit Number: T10CM03318
Permit Description: INSTALL:SOLAR ELECTRIC ROOF MOUNT
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/22/2010 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) SECURE BLOCK TO ROOF WITH TAR OR SUTIABLE PRODUCTS 2) TIGHTEN LOOSE LUG CONNECTIONS 3) ONLY ONE CONDUCTOR PER LUG CONNECTION 4) TIGHTEN LOOSE FITTINGS 5) PROVIDE PHSYICAL PROTECTION FOR PV CONDUITS 6) INSTALL WEEB LUGS PER MANUFACTURES INSTRUCTIONS 7) LABEL SERVICE PANEL PER 690.17 |