Permit: T10CM03189
Permit Details
Status:
Final
Type:
SINGLE FAMILY ALTERATION
Address:
4421 E PRESIDIO PL
Address NEW:
4421 E PRESIDIO PL
Apply Date:
11/12/2010
Applicant:
N/A
Description:
SOLAR WATER HEATER
Contractors:
- OLD WORLD CONSTRUCTION L L C
Permit Reviews
Permit Number - T10CM03189
Permit Status: Final
Permit Description: SOLAR WATER HEATER
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/12/2010 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 11/15/2010 | ACTIVE |
Outstanding Activity Conditions
Permit Number - T10CM03189
Permit Status: Final
Permit Description: SOLAR WATER HEATER
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/12/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T10CM03189
Permit Description: SOLAR WATER HEATER
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/02/2010 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection :* 1) GAS WATER HEATER REQUIRES 6" CLEARANCE IN FRONT OF BURNER 2) SEDIMENT TRAP REQ ON GAS SUPPLY 3) TYPE B VENT REQUIRED. SINGLE WALL TOUCHING WOOD IS A FIRE HAZARD. MIN TERMINATION IS 1' ABOVE ROOF 4) PROTECT TUBING PASSING THRU BRICK, AND RUBBING ON BACK 5) BEND OVER NAILS POKING THRU 6) SUPPORT ALL DOMESTIC PIPING 7) PROVIDE ACCESS TO TUBING IN ATTIC SPACE 8) SUPPORT AND PROTECT AS REQ. |
| 12/02/2010 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* |