Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/04/2011 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 01/11/2011 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) TYPE B VENT REQUIRES 1" MINIMUM CLEARANCE FROM COMBUSTIBLES 2) ACCESS TO ATTIC TUBING |
|
| 12/02/2010 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) GAS WATER HEATER REQUIRES 6" CLEARANCE IN FRONT OF BURNER 2) SEDIMENT TRAP REQ ON GAS SUPPLY 3) TYPE B VENT REQUIRED. SINGLE WALL TOUCHING WOOD IS A FIRE HAZARD. MIN TERMINATION IS 1' ABOVE ROOF 4) PROTECT TUBING PASSING THRU BRICK, AND RUBBING ON BACK 5) BEND OVER NAILS POKING THRU 6) SUPPORT ALL DOMESTIC PIPING 7) PROVIDE ACCESS TO TUBING IN ATTIC SPACE 8) SUPPORT AND PROTECT AS REQ. |