Permit Details

Status:
Expired
Type:
COMMERCIAL ALTERATION
Apply Date:
10/20/2010
Applicant:
N/A
Description:
TI:PARISH HALL
Contractors:
  • PIONEER PLUMBING INC ,

Permit Reviews

Permit Number - T10CM02915
Permit Status: Expired
Permit Description: TI:PARISH HALL
Start Date Submittal Complete Date Status  
01/11/2011 REVISION - - 1ST 01/11/2011 COMPLETED Review Details
05/31/2011 REVISION - - 2ND 06/01/2011 COMPLETED Review Details
06/01/2011 REVISION - - 2ND 06/10/2011 COMPLETED Review Details
10/20/2010 COMMERCIAL TI 10/22/2010 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T10CM02915
Permit Status: Expired
Permit Description: TI:PARISH HALL
Total Outstanding Activity Conditions - 1
Date Name
10/20/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T10CM02915
Permite Description: TI:PARISH HALL
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
BUILDING - FINAL N/A Not Inspected
11/29/2011 MECHANICAL - FINAL N/A Partial Approval IVRS - Inspection :*
1) EXTEND VENTS IN CONDENSATE DRAINS ABOVE FAN COIL DRAIN PANS
2) MARK FAN COIL DATA PLATES WITH HEAT STRIP AND FUSE ACCORDINGLY
3) MARK HEAT PUMP DATA PLATE
4) PROVIDE PROPER SUPPORT FOR MINI SPLIT CONDENSOR
5) PROVIDE A PROTECTIVE COATING ON EXPOSED ARMAFLEX TO MINIM SPLIT CONDENSOR
6) BLOCK AND CLAMP CONDENSATE DRAIN TO ROOF TOP UNIT
7) PROVIDE A FRESH AIR INTAKE ON ROOF TOP UNIT
8) PROVIDE A FRESH AIR INTAKE BALANCE REPORT
9) NEED TO TEST DUCT SMOKE DETECTORS AND PROVIDE AUDIBLE AND VISIBLE ALARMS

Completed Inspections

Permit Status: Expired
Permit Number: T10CM02915
Permit Description: TI:PARISH HALL
Total Completed Inspections - 9
Date Description Inspector Results Comments
02/14/2011 PLUMBING - PRE SLAB RRICH Approved IVRS - Inspection :*
02/14/2011 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
02/15/2011 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
03/07/2011 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
03/07/2011 PLUMBING - PROGRESS RRICH Approved IVRS - Inspection :$
08/05/2011 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
1) GET DIRECTION FROM ENGINEER ABOVE SECONDARY OVERFLOW SENSOR FOR FAN COILS
2) NEED TO SEE MINI SPLIT DRAIN CONNECTIONS
11/22/2011 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
11/22/2011 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection :*
11/29/2011 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*

Documents

File Name Document Type  
001_ A2-2.TIF CONSTRPLANS VIEW
002_ A3-3.TIF CONSTRPLANS VIEW
003_ P1-4.TIF CONSTRPLANS VIEW
004_ P2-5.TIF CONSTRPLANS VIEW
001_FLOOR PLAN.TIF CONSTRPLANS VIEW
002_FLOOR, EQUIPMENT, .TIF CONSTRPLANS VIEW
003_PLUMBING.TIF CONSTRPLANS VIEW
004_WASTE.TIF CONSTRPLANS VIEW
001_T-1.TIF CONSTRPLANS VIEW
002_M-1.TIF CONSTRPLANS VIEW
003_M-2.TIF CONSTRPLANS VIEW
004_M-3.TIF CONSTRPLANS VIEW
None CONSTRPLANS VIEW
None DOCUMENTS VIEW