Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
08/18/2010
Applicant:
N/A
Description:
TI & C OF O: RETAIL "TEAVANA"
Architects:
  • GOGLIA, FREDERICK J
Contractors:
  • WILLO DESIGN BUILD L L C

Permit Reviews

Permit Number - T10CM02281
Permit Status: C of o
Permit Description: TI & C OF O: RETAIL "TEAVANA"
Start Date Submittal Complete Date Status  
08/18/2010 PLANS OK TO SUBMIT - COMM 08/18/2010 COMPLETED Review Details
08/18/2010 COMMERCIAL TI 10/21/2010 COMPLETED Review Details
10/21/2010 RESUBMITTAL 11/18/2010 COMPLETED Review Details
11/18/2010 RESUBMITTAL 12/23/2010 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T10CM02281
Permit Status: C of o
Permit Description: TI & C OF O: RETAIL "TEAVANA"
Total Outstanding Activity Conditions - 1
Date Name
08/18/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T10CM02281
Permit Description: TI & C OF O: RETAIL "TEAVANA"
Total Completed Inspections - 26
Date Description Inspector Results Comments
01/10/2011 PLUMBING - PRE SLAB RRICH Approved IVRS - Inspection :*
01/10/2011 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
01/14/2011 BUILDING ABOVE CEILING GDABBS Approved IVRS - Inspection :*
01/18/2011 SHEET ROCK NAILING GDABBS Approved IVRS - Inspection :*
01/18/2011 FRAMING GDABBS Approved IVRS - Inspection :*
02/02/2011 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
APPROVED- FOR FINAL PROVIDE A CONDENSATE DRAIN TO THE MOP SINK, SCURE DIFFUSERS TO GRID, PROVIDE ACCESS TO ROOF, PROVIDE AIR BALANCE REPORT, PROGRAMS T-STAT SO FAR RUNS CONTINUOUSLY DURING OCCUPIED HOURS.
PROVIDE FIRE ALARM REPORT FOR DUCT SMOKE DETECTOR TEST.
02/02/2011 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
APPROVED
FOR FINAL PROVIDE A CONDENSATE DRAIN TO THE MOP SINK, SCURE DIFFUSERS TO GRID, PROVIDE ACCESS TO ROOF, PROVIDE AIR BALANCE REPORT, PROGRAMS T-STAT SO FAR RUNS CONTINUOUSLY DURING OCCUPIED HOURS.
PROVIDE FIRE ALARM REPORT FOR DUCT SMOKE DETECTOR TEST.
02/02/2011 FIRE SPKLR - FINAL LTHOMAS Approved
02/02/2011 FIRE - FINAL LTHOMAS Approved
02/04/2011 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
DUCT SMOKE DETECTOR TEST OK
OK FOR FINAL
02/04/2011 PLUMBING - PROGRESS RRICH Approved IVRS - Inspection :*
02/04/2011 PLUMBING - ABOVE CEILING RRICH Approved IVRS - Inspection :*
02/04/2011 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
02/04/2011 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
02/04/2011 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection :*
02/04/2011 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection :*
02/04/2011 SIGN - FINAL GDABBS Approved IVRS - Inspection :*
02/04/2011 NPPO - FINAL JFEMLING Approved Approved
02/04/2011 LANDSCAPE - FINAL JFEMLING Approved Approved
02/04/2011 ENGINEERING - FINAL JFEMLING Approved Approved
02/07/2011 HEALTH DEPT - FINAL 724-7908 NRAMIREZ Approved
02/07/2011 RIGHT OF WAY - FINAL PWHIDDON Approved
02/08/2011 PLUMBING - FINAL GDABBS Approved PER BLD FINAL
02/08/2011 BUILDING - FINAL GDABBS Approved IVRS - Inspection :*
02/08/2011 BUILDING - FINAL GDABBS Approved IVRS - Inspection :*
02/08/2011 CERTIFICATE OF OCCUPANCY GDABBS Approved IVRS - Inspection :*