Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
9642 E RAND PL
Address NEW:
9642 E RAND PL
Apply Date:
05/04/2010
Applicant:
N/A
Description:
REPLACE GROUND MOUNT HVAC SYSTEM
Contractors:
  • MC CALL S QUALITY SERVICES INC

Permit Reviews

Permit Number - T10CM01225
Permit Status: Expired
Permit Description: REPLACE GROUND MOUNT HVAC SYSTEM
Start Date Submittal Complete Date Status  
05/04/2010 OTHER 05/04/2010 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T10CM01225
Permit Status: Expired
Permit Description: REPLACE GROUND MOUNT HVAC SYSTEM
Total Outstanding Activity Conditions - 1
Date Name
05/04/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T10CM01225
Permite Description: REPLACE GROUND MOUNT HVAC SYSTEM
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
05/06/2010 MECHANICAL - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LOW VOLTAGE WIRE CANNOT BE EXPOSED TO DAMAGE BY RODENTS
2) PROVIDE A PROTECTIVE COATING ON EXPOSED ARMA FLEX
3) PROVIDE THE REQUIRED GFI SERVICE RECEPT AT THE CONDENSOR
4) PVC CANNOT BE WITHIN 6" OF THE FURNACE VENT CONNECTOR
5) PROVIDE HOSE CLAMPS AT PLASTIC HOSE CONNECTIONS
6) PROVIDE MINIMUM 3 SCREWS IN ALL JOINTS OF VENT CONNECTOR
7) DO NOT USE A 3 WAY ADAPTOR FOR FURNACE AND PUMP
8) PROVIDE THE REQUIRED SEDIMENT TRAP IN GAS LINE
9) PROVIDE AN ESCUTCHEON AROUND DBL WALL VENT AT CEILING PENETRATION
10) DO NOT TERMINATE CONDENSATE INTO A SEWER VENT. TERMINATE TO WITHIN 6" OF THE GROUND. SUPPORT COPPER LINE ON ROOF EVERY 6'

Completed Inspections

Permit Status: Expired
Permit Number: T10CM01225
Permit Description: REPLACE GROUND MOUNT HVAC SYSTEM
Total Completed Inspections - 1
Date Description Inspector Results Comments
05/06/2010 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*

Documents

File Name Document Type  
None DOCUMENTS VIEW