Permit: T10CM01169
Permit Details
Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
4500 N ORACLE RD #341
Address NEW:
4500 N ORACLE RD #341
Apply Date:
04/28/2010
Applicant:
N/A
Description:
RESTAURANT
Architects:
- LENCIONI, JAMES RUDOLPH
Contractors:
- ALFREDO ANNINO CONSTRUCTION OF ARIZONA INC
Permit Reviews
Permit Number - T10CM01169
Permit Status: C of o
Permit Description: RESTAURANT
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/28/2010 | PLANS OK TO SUBMIT - COMM | 04/29/2010 | COMPLETED |
| 04/29/2010 | COMMERCIAL TI | 05/27/2010 | COMPLETED |
| 05/27/2010 | RESUBMITTAL - TI ALL | 06/23/2010 | COMPLETED |
| 06/23/2010 | RESUBMITTAL | 06/30/2010 | COMPLETED |
| 06/30/2010 | RESUBMITTAL | 07/01/2010 | COMPLETED |
| 07/20/2010 | REVISION - - 1ST | 07/30/2010 | COMPLETED |
| 08/02/2010 | REVISION - - 2ND | 08/10/2010 | COMPLETED |
| 08/10/2010 | REVISION - - 2ND | 08/12/2010 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T10CM01169
Permit Status: C of o
Permit Description: RESTAURANT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/28/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T10CM01169
Permit Description: RESTAURANT
Total Completed Inspections - 35
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/23/2010 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :* 1) WATER TEST UNDERGROUND THRU TO ABOVE CLEANOUT HEIGHT OK GREASE WASTE 2) SLEEVES FOR UNDER SLAB WATER IN PLACE |
| 07/30/2010 | PLUMBING - PRE SLAB | RMYERS | Approved | IVRS - Inspection :* 1) OK FOR CONCRETE |
| 08/02/2010 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/04/2010 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/12/2010 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/30/2010 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 09/13/2010 | ZONING - FINAL | pgehlen | Approved | |
| 09/14/2010 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 09/15/2010 | BUILDING - PROGRESS | AQUIROZ | Approved | IVRS - Inspection :* 1) STUCCO OK |
| 09/30/2010 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection :* 1) INSULATION OK |
| 10/06/2010 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* |
| 10/13/2010 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection :* |
| 10/13/2010 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* |
| 10/13/2010 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 10/25/2010 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | IVRS - Inspection :* 1) UNLESS YOU POST A BOND, GAS CARD IS LEFT BY BLDG INSPECTOR AFTER YOU PASS THE FINAL INSPECTION 2) WHEN MECHANICAL APPROVES ROOF TOP-OK FOR GAS |
| 10/26/2010 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* |
| 10/26/2010 | RIGHT OF WAY - FINAL | M.Otero | Approved | |
| 10/27/2010 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection :* |
| 10/27/2010 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection :* |
| 10/27/2010 | NPPO - FINAL | MRUSSO | Approved | |
| 10/27/2010 | LANDSCAPE - FINAL | MRUSSO | Approved | |
| 10/28/2010 | ELECTRIC - PROGRESS | DSANTACR | Approved | IVRS - Inspection :* |
| 10/28/2010 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* |
| 10/28/2010 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 10/29/2010 | MECHANICAL - HOODS | MRAMBER | Approved | IVRS - Inspection :* |
| 10/29/2010 | SIGN - FINAL | JYBARRA | Approved | |
| 11/01/2010 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :* 1) G.C. INDICATED THAT DUE TO THE DUCT SMOKE DETECTORS BEING TIED TO THE MALL FIRE ALARM SYSTEM THAT THE FIRE MARSHALL WILL BE TESTING THOSE WHEN COMPLETE FIRE SYSTEM IS TESTED |
| 11/01/2010 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* |
| 11/02/2010 | FIRE - KITCHEN EXH HOOD FINAL | DSiwerski | Approved | Approved 11/1/10 |
| 11/02/2010 | FIRE - ALARM FINAL | DRamirez | Approved | Approved 11/2/10 |
| 11/02/2010 | FIRE - FINAL | DRamirez | Approved | Approved 11/2/10 |
| 11/03/2010 | PLUMBING - FINAL | RMYERS | Approved | |
| 11/03/2010 | HEALTH DEPT - FINAL 724-7908 | NRAMIREZ | Approved | |
| 11/03/2010 | BUILDING - FINAL | JBURGE | Approved | |
| 11/03/2010 | ENGINEERING - FINAL | MRUSSO | Approved |