Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
03/12/2010
Applicant:
N/A
Description:
SFR GVPH233108 T08-M0112
Contractors:
  • G V PREMIER HOMES L L C

Permit Reviews

Permit Number - T10CM00607
Permit Status: C of o
Permit Description: SFR GVPH233108 T08-M0112
Start Date Submittal Complete Date Status  
03/12/2010 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 03/12/2010 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T10CM00607
Permit Status: C of o
Permit Description: SFR GVPH233108 T08-M0112
Total Outstanding Activity Conditions - 1
Date Name
03/12/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T10CM00607
Permit Description: SFR GVPH233108 T08-M0112
Total Completed Inspections - 25
Date Description Inspector Results Comments
03/30/2010 PLUMBING - SEWER HCS CONNECT RFREIDIN Approved IVRS - Inspection :*
03/30/2010 PLUMBING - YARD WTR LINE/TEST RFREIDIN Approved IVRS - Inspection :*
03/30/2010 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection :*
04/07/2010 ELECTRIC - UNDERGROUND RFREIDIN Approved IVRS - Inspection :*
04/07/2010 BUILDING PRE-SLAB RFREIDIN Approved IVRS - Inspection :*
04/09/2010 ELECTRIC - UFER RFREIDIN Approved IVRS - Inspection :*
04/09/2010 EXCAVATION/LAYOUT REBAR & ZON RFREIDIN Approved IVRS - Inspection :*
04/20/2010 EXT METAL CLIPS/EXT SHEATHING GDABBS Approved IVRS - Inspection :*
1) NOTE: NUT MISSING AT #3 HOLDOWN AT DOOR FROM GARAGE TO UTILITY APPROVED
04/20/2010 ROOF NAILING GDABBS Approved IVRS - Inspection :*
05/05/2010 ELECTRIC - TEMPORARY SERVICE DQUINN Approved IVRS - Inspection :*
05/05/2010 ELECTRIC - CABLE DROP DQUINN Approved IVRS - Inspection :*
05/20/2010 MECHANICAL - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
05/20/2010 PLUMBING - GAS PRESSURE TEST RFREIDIN Approved IVRS - Inspection :*
05/20/2010 PLUMBING - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
05/20/2010 U VALUE FOR WINDOW RFREIDIN Approved IVRS - Inspection :*
05/20/2010 STUCCO MESH RFREIDIN Approved IVRS - Inspection :*
05/21/2010 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER R. FREIDINGER
05/26/2010 FRAMING RFREIDIN Approved IVRS - Inspection :*
1) GARAGE ROOF LPI 32 PLUS INSTALLED, PLAN CALLS FOR T.J.I. 360
2) I DON'T HAVE LPI BOOK, I DON'T KNOW WHAT SIZE TOP/BOTTOM CORDS ARE TO HAVE CHANGE ON PLAN OR LPI
05/26/2010 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
06/08/2010 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection :*
07/28/2010 MECHANICAL - FINAL DQUINN Approved IVRS - Inspection :*
07/28/2010 PLUMBING - FINAL DQUINN Approved IVRS - Inspection :*
07/28/2010 ELECTRIC - FINAL DQUINN Approved IVRS - Inspection :*
07/28/2010 BUILDING - FINAL DQUINN Approved IVRS - Inspection :*
07/30/2010 PERMIT FINALED JWEATHER Approved