Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
01/28/2010
Applicant:
N/A
Description:
SFR: TJBE153608 T08-M0088
Contractors:
  • T J BEDNAR & COMPANY

Permit Reviews

Permit Number - T10CM00227
Permit Status: C of o
Permit Description: SFR: TJBE153608 T08-M0088
Start Date Submittal Complete Date Status  
01/28/2010 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 02/02/2010 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T10CM00227
Permit Status: C of o
Permit Description: SFR: TJBE153608 T08-M0088
Total Outstanding Activity Conditions - 1
Date Name
01/28/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T10CM00227
Permit Description: SFR: TJBE153608 T08-M0088
Total Completed Inspections - 24
Date Description Inspector Results Comments
02/25/2010 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection :*
1) DON'T BACKFILL UNTIL PROPERTY PIN ON NORTH SIDE VERIFIED
02/25/2010 PLUMBING - SEWER HCS CONNECT RFREIDIN Approved IVRS - Inspection :*
02/25/2010 PLUMBING - YARD WTR LINE/TEST RFREIDIN Approved IVRS - Inspection :*
03/04/2010 ELECTRIC - UFER DQUINN Approved IVRS - Inspection :*
03/04/2010 BUILDING PRE-SLAB DQUINN Approved IVRS - Inspection :*
03/04/2010 EXCAVATION/LAYOUT REBAR & ZON DQUINN Approved IVRS - Inspection :*
03/23/2010 ELECTRIC - TEMPORARY SERVICE RFREIDIN Approved IVRS - Inspection :*
03/23/2010 ELECTRIC - CABLE DROP RFREIDIN Approved IVRS - Inspection :*
03/24/2010 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER R. FREIDINGER
03/29/2010 ROOF NAILING DQUINN Approved IVRS - Inspection :*
03/29/2010 EXT METAL CLIPS/EXT SHEATHING DQUINN Approved IVRS - Inspection :*
04/06/2010 MECHANICAL - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
04/06/2010 U VALUE FOR WINDOW DQUINN Approved IVRS - Inspection :*
04/06/2010 STUCCO MESH DQUINN Approved IVRS - Inspection :*
04/07/2010 FRAMING DQUINN Approved IVRS - Inspection :*
04/07/2010 PLUMBING - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
04/07/2010 ELECTRIC - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
04/19/2010 SHEET ROCK NAILING DQUINN Approved IVRS - Inspection :*
06/04/2010 OUTDOOR LIGHTING FINAL DQUINN Approved
06/04/2010 MECHANICAL - FINAL DQUINN Approved IVRS - Inspection :*
06/04/2010 PLUMBING - FINAL DQUINN Approved IVRS - Inspection :*
06/04/2010 ELECTRIC - FINAL DQUINN Approved IVRS - Inspection :*
06/04/2010 BUILDING - FINAL DQUINN Approved IVRS - Inspection :*
06/10/2010 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
C OF O_06-10-2010.TIF CERT OF OCC VIEW
None DOCUMENTS VIEW
SITE PLAN_01-28-2010.TIF CONSTRPLANS VIEW