Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/29/2010 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 03/24/2010 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) REAR SHEARWALL <6> A, "B" TYPE P.A. REQUIRED MTT26-B, HTT16 INSTALLED 2) MISSED STHD 8 REGD. , NORTH WALL 4'-8' PANEL, 4'-0" HTT16 INSTALLED 3) REAR SHEARWALL TIE TOP OF WALL TO TRUSS BOTTOM CHORD USE 413/S.D. 4) ITEM #1 WHAT IS RETRO FIX FOR MTT26-B NORTH WALL 5) NEED TRUSS DRAWINGS 6) SHEAR TRANSFER WALL MID POINT LIVING ROOM PERPENDICULAR TO TRUSSES SHEAR PANELS BETWEEN TRUSSES FOR TRANSFER TO ROOF TO BE NAILED 3" ON CENTER TO ROOF DECK SHIM SPACE BETWEEN ROOF DECK TO PANEL 7) BEFORE FINAL FRAME NAIL LADDER BLOCK SHEAR CONNECTIONS TO ROOF TOP PLATES AT PARALELL SITUATIONS 8) NEED DETAIL OF EXT. BEARING WALL TO TRUSS 9) MISSING NAILING ROOF STAPLES NAIL AT 3"-6" ON CENTER |