Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address NEW:
5425 E WAVERLY ST
Apply Date:
12/28/2009
Applicant:
GONZALEZ MAX & MERCEDES M CP/RS
Description:
REPLACE:GAS LINE

Permit Reviews

Permit Number - T09PL02192
Permit Status: Final
Permit Description: REPLACE:GAS LINE
Start Date Submittal Complete Date Status  
12/28/2009 PLUMBING 12/28/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09PL02192
Permit Status: Final
Permit Description: REPLACE:GAS LINE
Total Outstanding Activity Conditions - 1
Date Name
12/28/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T09PL02192
Permit Description: REPLACE:GAS LINE
Total Completed Inspections - 3
Date Description Inspector Results Comments
12/30/2009 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) EXPOSE PIPING COVERED WITHOUT INSPECTION
2) YELLOW TRACER WIRE REQUIRED WITH NON METALLIC PIPING. 1" REQUIRED 18" OF COVER REQUIRED. CONNECT NEW YARD LINE TO HOUSE AND PROVIDE A TEST ON THE ENTIRE SYSTEM
3) INSTALL LISTED GAS VALVES AND FLEXES
4) CHECK T & P RELIEF VALVE FOR PROPER OPERATION
5) SECURE VENT CONNECTORS WITH SCREWS
6) COMBUSTION AIR OPENINGS
7) A CLOSED LOOP SYSTEM WITH A CHECK VALVE REQUIRES AN EXPANSION TANK
8) SOLAR SYSTEMS AND NEW WHS REQUIRES PERMITS
12/30/2009 PLUMBING - GAS PRESSURE TEST BBENEDON Approved IVRS - Inspection :
See detailed listing on site.| 999*
01/06/2010 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW