Description:
RECONNECT:GAS LINE & REPLACE: WATER HEATER

Permit Reviews

Permit Number - T09PL01784
Permit Status: Expired
Permit Description: RECONNECT:GAS LINE & REPLACE: WATER HEATER
Start Date Submittal Complete Date Status  
10/30/2009 PLUMBING 10/30/2009 ACTIVE Review Details

Outstanding Activity Conditions

Permit Number - T09PL01784
Permit Status: Expired
Permit Description: RECONNECT:GAS LINE & REPLACE: WATER HEATER
Total Outstanding Activity Conditions - 1
Date Name
10/30/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T09PL01784
Permite Description: RECONNECT:GAS LINE & REPLACE: WATER HEATER
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
11/02/2009 PLUMBING - FINAL N/A Not ready for Inspection IVRS - Inspection :*
WATER HEATER:
1) TEMPERATURE AND PRESSURE RELIEF DRAIN TO GRAVITY TO DAYLIGHT WITH NO FLEX
2) ELECTRICAL JUNCTION BOX ON HEATER TO BE PROPERLY TERMINATED
3) WATER HEATER BREAKERS TO BE IDENTIFIED IN ELECTRICAL PANEL
11/10/2009 PLUMBING - GAS PRESSURE TEST N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEE NOTE #1 FROM 11/02/09 INSPECTION
2) MAXIMUM BREAKER IN ELECTRICAL PANEL FOR 4500 WATTS AT WATER HEATER TO BE 30 AMP BREAKERS
3) 03050-TEST MUST HOLD 10 PSI FOR MINIMUM 15 MINUTES WITH NO LOSS OF PRESSURE