Permit: T09PL01708
Permit Details
Apply Date:
10/19/2009
Applicant:
GEORGE HUFF PLUMBING *C
Description:
GAS LINE UPGRADE (APA)
Contractors:
- GEORGE HUFF PLUMBING *C
Permit Reviews
Permit Number - T09PL01708
Permit Status: Expired
Permit Description: GAS LINE UPGRADE (APA)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/19/2009 | PLUMBING | 10/19/2009 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09PL01708
Permit Status: Expired
Permit Description: GAS LINE UPGRADE (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/19/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T09PL01708
Permite Description: GAS LINE UPGRADE (APA)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/20/2009 | PLUMBING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE CORRECT BOND OF BLDG GAS SYSTEM, YOU CAN USE A SPLIT BOLT TO THE EXISTING GROUNDING WIRE (CLEAN IT 1ST) YOU CANNOT HAVE 2 WIRES UNDER THE SAME LUG IN DISCONNECT BOX 2) SEAL T & P DRAIN HOLE THRU BLDG EXTERIOR 3) PROVIDE APPROVED DBL WALL VENT CAP |
Completed Inspections
Permit Status: Expired
Permit Number: T09PL01708
Permit Description: GAS LINE UPGRADE (APA)
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/20/2009 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* 1) GAS CARD AT METER |