Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
DUPLEX OTHER
Apply Date:
09/04/2009
Applicant:
DAVID KLEIN
Description:
RECONNECT:GAS:DUPLEX

Permit Reviews

Permit Number - T09PL01482
Permit Status: Expired
Permit Description: RECONNECT:GAS:DUPLEX
Start Date Submittal Complete Date Status  
12/24/2009 PLUMBING 12/24/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09PL01482
Permit Status: Expired
Permit Description: RECONNECT:GAS:DUPLEX
Total Outstanding Activity Conditions - 1
Date Name
09/04/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T09PL01482
Permite Description: RECONNECT:GAS:DUPLEX
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
12/29/2009 PLUMBING - INTERMEDIATE N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/29/2009 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) I WILL ACCEPT BELOW GRADE EXTERIOR GAS PIPING INSTALLED WITHOUT INSPECTION TEST HOLDING
AT NEW WATER HEATERS:
1) INSTALL TYPE B VENT PER IT'S LISTING (INSTALLATION INSTRUCTIONS) WITH APPROVED CAP
2) ALL VENT PIPE OUTSIDE OF ENCLOSURE IS REQUIRED TO BE DBL WALL
3) PROVIDE PROPER T & P TERMINATION
4) PROVIDE SEDIMENT TRAP
5) HOSE BIB REQUIRES VACUUM BREAKERS
6) ALL EXTERIOR VENT PIPES REQUIRE UV PROTECTION
INSIDE BLDG:
1) ALL WORK HAS BEEN COVERED WITHOUT INSPECTIONS, EXPOSE ENOUGH TO SEE YOUR CONNECTIONS TO EXISTING PIPES, AS PREVIOUSLY DISCUSSED
2) AT TUB DIVERTER AND DRAIN, UNDER KS
3) NEW DRAIN PIPING AND NEW WATER PIPING REQUIRE INSPECTION

Completed Inspections

Permit Status: Expired
Permit Number: T09PL01482
Permit Description: RECONNECT:GAS:DUPLEX
Total Completed Inspections - 1
Date Description Inspector Results Comments
12/29/2009 PLUMBING - GAS PRESSURE TEST BBENEDON Approved IVRS - Inspection :*

Documents

File Name Document Type  
None CONSTRPLANS VIEW
None DOCUMENTS VIEW