Permit: T09PL00716
Permit Details
Apply Date:
04/23/2009
Applicant:
RUBEN TRASBANA
Description:
RECONNECT: GAS, MH
Outstanding Activity Conditions
Permit Number - T09PL00716
Permit Status: Expired
Permit Description: RECONNECT: GAS, MH
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
04/23/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T09PL00716
Permite Description: RECONNECT: GAS, MH
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/30/2009 | PLUMBING - GAS PRESSURE TEST | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) VENT/FLUE NEED DBL WALL CONNECTED TO AMBER VENT THRU ROOF 2) NEED 10 POUND PRESSURE TO HOLD FOR MINIMUM 15 MINUTES 3) NEED WORKING T & P VALVE, WITH 3/4" DIAMETER LINE DOWN TO GRADE 4) NEED A SHUT OFF VALVE FOR COLD SIDE OF H20 SUPPLY 5) VALVE FLEX CONNECTION IS RUSTED 6) FURNACE/HEAT SOURCE REQUIRED FOR UNIT. GAS RUNS TO INSIDE OWNER CLAIMS NO GAS FURNACE 7) REMOVE PANEL ABOVE FURNACE TO VERIFY FLUE CONNECTION AND COMB/RELIEF AIR |