Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
3707 E HELENA SV
Apply Date:
12/30/2009
Applicant:
ANNE POUBIN
Description:
RECONNECT: ELECTRIC
Contractors:
  • MEHL ELECTRIC SERVICE INC, *C*

Outstanding Activity Conditions

Permit Number - T09EL02811
Permit Status: Final
Permit Description: RECONNECT: ELECTRIC
Total Outstanding Activity Conditions - 1
Date Name
12/30/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T09EL02811
Permit Description: RECONNECT: ELECTRIC
Total Completed Inspections - 4
Date Description Inspector Results Comments
12/31/2009 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1) SECURE CONDUIT AND BOXES TO CARPORT WALL
2) GROUNDED RECEPTS ON UNGROUNDED CIRCUITS
3) KITCHEN RECEPTS TO BE GFCI PROTECTED
4) SUPPORT FIXTURES ABOVE GRID TYPE CEILING-USE APPROVED WIRING METHODS AND EXPOSED CONDUCTORS
5) PROTECT CABLE BEHIND WHERE RANGE WOULD BE
6) SMOKE DETECTORS NEEDED FOR BEDROOMS AND HALL
7) BATHROOM RECEPTS TO BE GFCI PROTECTED
8) MAINTAIN WORKING CLEARANCE IN FRONT OF SUB PANEL
9) REATTACH GROUNDING ELECTRODE CONDUCTOR TO STRUCTURE
10) RE-ATTACH GAS AND WATER BONDS
11) PROPERLY TERMINATE GROUNDED AND GROUNDING CONDUCTORS AT MAIN DISCONNECT
12) OUTDOOR RECEPTS TO BE FOR WET LOCATION
13) EXPOSED CONDUCTORS AND CABLES BACK PORCH
14) FILL UNUSED OPENING IN SUB PANEL BACK AND COVER
12/31/2009 ELECTRIC - RECONNECT RHOLLAND Approved IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
05/25/2010 TEP CLEARANCE - AM JWEATHER Approved RECN CLEARED PER R. HOLLANDER
05/25/2010 PERMIT FINALED JWEATHER Approved