Permit: T09EL02811

Parcel: 140061170


Addresses:

3707 E HELENA SV


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T09EL02811

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/24/2010 ELECTRIC - FINAL Approved IVRS - Inspection :*
05/21/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING FIXTURES
2) MISSING PLUMBING BATHROOMS
3) FINISH #1, 6 & 11 PREVIOUS INSPECTION
4) UNIT IS NOT HABITABLE
12/31/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1) SECURE CONDUIT AND BOXES TO CARPORT WALL
2) GROUNDED RECEPTS ON UNGROUNDED CIRCUITS
3) KITCHEN RECEPTS TO BE GFCI PROTECTED
4) SUPPORT FIXTURES ABOVE GRID TYPE CEILING-USE APPROVED WIRING METHODS AND EXPOSED CONDUCTORS
5) PROTECT CABLE BEHIND WHERE RANGE WOULD BE
6) SMOKE DETECTORS NEEDED FOR BEDROOMS AND HALL
7) BATHROOM RECEPTS TO BE GFCI PROTECTED
8) MAINTAIN WORKING CLEARANCE IN FRONT OF SUB PANEL
9) REATTACH GROUNDING ELECTRODE CONDUCTOR TO STRUCTURE
10) RE-ATTACH GAS AND WATER BONDS
11) PROPERLY TERMINATE GROUNDED AND GROUNDING CONDUCTORS AT MAIN DISCONNECT
12) OUTDOOR RECEPTS TO BE FOR WET LOCATION
13) EXPOSED CONDUCTORS AND CABLES BACK PORCH
14) FILL UNUSED OPENING IN SUB PANEL BACK AND COVER