Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
320 N EUCLID AV
Address NEW:
320 N EUCLID AV
Apply Date:
08/31/2009
Applicant:
S AND D ELECTRIC INC *C
Description:
UPGRADE:ELECTRIC TO 100AMP (APA)
Contractors:
  • S AND D ELECTRIC INC *C

Outstanding Activity Conditions

Permit Number - T09EL02003
Permit Status: Expired
Permit Description: UPGRADE:ELECTRIC TO 100AMP (APA)
Total Outstanding Activity Conditions - 1
Date Name
08/31/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T09EL02003
Permite Description: UPGRADE:ELECTRIC TO 100AMP (APA)
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
ELECTRIC - SERVICE UPGRADE N/A Not Inspected
09/03/2009 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. INSTALL PROTECTIVE BUSHING ON ENDS OF EMT WHERE WIRES ENTER
2. INSTALL BREAKERS LISTED FOR USE IN SIEMENS PANEL
3. STRAP EMT TO WITHIN 3' OF CONNECTIONS
4. BENDS ON 3/4" EMT HAVE REDUCED INTERNAL DIAMETER
5. CANNOT USE WHITE CONDUCTORS IN RACEWAY AS PHASE CONDUCTORS
6. INSTALL SEALING WASHERS AT CONDUIT ENTRY IN TOP OF PANEL OR INSTALL MEYERS HUBS
7. WILL NEED PERMIT FOR NEW WATER HEATER
8. EXPOSE GROUND RODS
9. LUG IN SERVICE PANEL NOT LISTED FOR 2 WIRE TERMINATION

Documents

File Name Document Type  
None DOCUMENTS VIEW