Permit: T09CM03280
Permit Details
Apply Date:
12/14/2009
Applicant:
N/A
Description:
ADDITION:BEDROOM/BATH
Permit Reviews
Permit Number - T09CM03280
Permit Status: Final
Permit Description: ADDITION:BEDROOM/BATH
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/22/2010 | RESUBMITTAL | 02/12/2010 | COMPLETED |
02/29/2012 | REVISION - - 3RD | 04/07/2015 | COMPLETED |
03/12/2010 | REVISION - - 1ST | 03/12/2010 | COMPLETED |
08/27/2010 | REVISION - - 2ND | 08/27/2010 | COMPLETED |
12/14/2009 | RESIDENTIAL BLDG/ZONING/ENGINE/NPPO | 12/14/2009 | COMPLETED |
12/14/2009 | RESIDENTIAL BLDG/ZONING/ENGINE/WWM | 01/22/2010 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09CM03280
Permit Status: Final
Permit Description: ADDITION:BEDROOM/BATH
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
12/14/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T09CM03280
Permit Description: ADDITION:BEDROOM/BATH
Total Completed Inspections - 26
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/06/2010 | PLUMBING - ROUGH, SOIL | DQUINN | Approved | IVRS - Inspection :* |
04/12/2010 | EXCAVATION/LAYOUT REBAR & ZON | GDABBS | Approved | ALL HOSES CONNECTIONS REQUIRES VACUUM BREAKERS FOR PUBLIC SAFETY YARD LINE OK |
05/04/2010 | PLUMBING - PRE SLAB | GDABBS | Approved | IVRS - Inspection :* |
05/04/2010 | BUILDING PRE-SLAB | GDABBS | Approved | IVRS - Inspection :* |
05/24/2010 | BUILDING ABOVE CEILING | RCAMACHO | Approved | IVRS - Inspection :* |
07/07/2010 | EXT METAL CLIPS/EXT SHEATHING | RCAMACHO | Approved | |
08/31/2010 | FRAMING | RCAMACHO | Approved | IVRS - Inspection :* 1) EXCEPT BREAKTHROUGH/COMPLETE ALL TRADES 2) MISSING OUTLET PER CODE 24" WALL SPACE 3) SECOND ROMEX 8" FROM BOXES 4) SUBMIT AS BUILT FOR BREAKTHROUGH NOT ON PLAN |
08/31/2010 | ELECTRIC - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
08/31/2010 | STUCCO MESH | RCAMACHO | Approved | IVRS - Inspection :* |
08/31/2010 | ROOF NAILING | RCAMACHO | Approved | IVRS - Inspection :* |
08/23/2011 | PLUMBING - GAS PRESS TEST FNL | DWALKER | Approved | OK TO MOVE METER. GAS LINE UNDER ADDITION SLAB ISSUED GAS TAG ONLY FOR THIS PURPOSE NEED #8 BOND ON NEW LINE WILL SEE AT FINALS |
03/01/2012 | ELECTRIC - SERVICE RELOCATION | MRAMBER | Approved | IVRS - Inspection :* |
03/05/2012 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO/RELOCATE CLEARED PER M. RAMBER |
08/27/2012 | ELECTRIC - CABLE DROP | MRAMBER | Approved | IVRS - Inspection :* |
10/31/2013 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* MAIN CEILING AREA - OK TO TAPE |
10/01/2015 | PLUMBING - INTERMEDIATE | JMILITEL | Approved | PROVIDE TEST ON PLUMBING |
10/01/2015 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
03/16/2016 | MECHANICAL - FINAL | RMORENO | Approved | IVRS - Inspection :* |
03/10/2017 | PLUMBING - ABOVE CEILING | bbenedon | Approved | |
09/06/2017 | ELECTRIC - FINAL | mpugh1 | Approved | isolate neutrals and grounds at sub panel, run ground with 20 amp two pole circuit. |
02/23/2018 | PLUMBING - MEDICAL GAS/FINAL | bbenedo1 | Approved | |
12/13/2018 | PLUMBING - FINAL | DMCCARTHY | Approved | no plumbing fixtures are installed in a residential bathroom explain to homeowner to call for finals when off pictures are done at the end of the job Customer was probably trying to keep his building permit open , So he scheduled an inspection keep the permit active |
06/03/2019 | ELECTRIC - PROGRESS | RCAMACHO | Approved | APPROVED PER 1090 APPROVAL |
06/03/2019 | ELECTRIC - ABOVE CEILING | RCAMACHO | Approved | APPROVED PER 1090 APPROVAL |
06/03/2019 | BUILDING - PROGRESS | RCAMACHO | Approved | |
06/03/2019 | BUILDING - FINAL | RCAMACHO | Approved |