Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
825 E OREGON ST
Apply Date:
12/09/2009
Applicant:
N/A
Description:
NEW:A/C UNIT:WATER HEATER

Permit Reviews

Permit Number - T09CM03235
Permit Status: Final
Permit Description: NEW:A/C UNIT:WATER HEATER
Start Date Submittal Complete Date Status  
12/09/2009 OTHER 12/09/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09CM03235
Permit Status: Final
Permit Description: NEW:A/C UNIT:WATER HEATER
Total Outstanding Activity Conditions - 3
Date Name
12/09/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
12/09/2009 SPECIAL INSPECTION FORMS AND REPORTS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY.
12/09/2009 SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED.

Completed Inspections

Permit Status: Final
Permit Number: T09CM03235
Permit Description: NEW:A/C UNIT:WATER HEATER
Total Completed Inspections - 2
Date Description Inspector Results Comments
12/30/2009 MECHANICAL - FINAL MRAMBER Approved IVRS - Inspection :
1. ALL DUCT EXPOSED TO EXTERIOR IS TO BE INSULATED TO A MINIMUM OF R8 (2") PER 2006 IECC
2. PROVIDE APPROVED CONNECTION ON LINE VOLTAGE CONDUIT.
3. CONDENSATE IS TO TERMINATE WITHIN 6" OF GRADE.
4. ALL PVC PIPE EXPOSED TO EXTERIOR TO BE PAINTED AND BLOCKED UP OFF OF ROOF A MINIMUM OF 1.5"
5. PROVIDE UNIT DATA PLATE
12/30/2009 PLUMBING - FINAL RLEDONNE Approved IVRS - Inspection :*
1. REMOVE FLEX ON T&P PROVIDE FULL SIZE PIPING AT WATER HEATER
2. PROVIDE PAN UNDER WATER HEATER
3. PROVIDE LADDER

Documents

File Name Document Type  
None DOCUMENTS VIEW