Permit: T09CM03233
Permit Details
Apply Date:
12/08/2009
Applicant:
N/A
Description:
REPL WATER HEATER AND ELEC TO PORCH
Outstanding Activity Conditions
Permit Number - T09CM03233
Permit Status: Final
Permit Description: REPL WATER HEATER AND ELEC TO PORCH
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 12/08/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 12/08/2009 | SPECIAL INSPECTION FORMS AND REPORTS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. |
Completed Inspections
Permit Status: Final
Permit Number: T09CM03233
Permit Description: REPL WATER HEATER AND ELEC TO PORCH
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/16/2009 | ELECTRIC - FINAL | EDURAZO | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) 1" CLEARANCE REQUIRED AT WATER HEATER B-VENT TO COMBUSTIBLE 2) PTR LINE SHALL EXTEND TO EXTERIOR OF STORAGE AND DISCHARGE DOWNWARD 6" MIN 24" MAX FROM THE GROUND. COPPER, GALV. OR CPVC PIPE 3) REPLACE ALL PVC WATER LINES ABOVE GROUND WITH COPPER CPVC OR GALVENIZED LINES 4) 3 SCREWS REQUIRED AT ALL VENT JOINTS AT WATER HEATER 5) SEDIMENT TRAP MISSING AT WATER HEATER GAS LINE 6) EXPOSE J-BOXES AT ELECTRICAL FOR INSPECTION |
| 12/16/2009 | PLUMBING - FINAL | EDURAZO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |