Permit: T09CM03118
Permit Details
Status:
Final
Type:
SINGLE FAMILY ADDITION
Address:
4917 E BERMUDA ST
Address NEW:
4917 E BERMUDA ST
Apply Date:
11/25/2009
Applicant:
N/A
Description:
SOLAR WATER HEATER
Contractors:
- RUSSETT SERVICE CORPORATION, *C
Permit Reviews
Permit Number - T09CM03118
Permit Status: Final
Permit Description: SOLAR WATER HEATER
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/09/2010 | REVISION - - 2ND | 02/09/2010 | COMPLETED |
| 11/25/2009 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 11/25/2009 | COMPLETED |
| 12/10/2009 | REVISION - - 1ST | 02/02/2010 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09CM03118
Permit Status: Final
Permit Description: SOLAR WATER HEATER
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/25/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T09CM03118
Permit Description: SOLAR WATER HEATER
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/11/2009 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE A PERMIT FOR NEW ELECTRICAL WIRING 2) PROVIDE A CITY APPROVED PLAN WITH PIPING DIAGRAM FOR INSTALLATION 3) BRASS OR DIELECTRIC PROTECTION AT WATER HEATER DRAIN CONNECTION 4) MIXING VALVE REQUIRED 5) PIPING NOT SOLDERED AT T & P VALVE 6) SOLAR PANEL AND ALL PIPING SHALL BE SUPPORTED WITH CLEARANCE ABOVE FLAT ROOF, WHERE NAILS HAVE BEEN DRIVEN INTO ROOFING, THE ROOF SHALL BE PROPERLY PATCHED |
| 12/11/2009 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 06/29/2010 | ELECTRIC - FINAL | BBENEDON | Approved | IVRS - Inspection :* 1) SECURE ELECTRICAL OUTLET AND DISCONNECT BOX TO WALL |
| 07/01/2010 | PERMIT FINALED | JWEATHER | Approved |