Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
6609 E MARY DR
Address NEW:
6609 E MARY DR
Apply Date:
11/19/2009
Applicant:
N/A
Description:
REPLACE:EVAP COOLER WITH A/C CONDENSER ON ROOF, REPLACE:FURNACE INSIDE BUILDING T09CM03052

Permit Reviews

Permit Number - T09CM03052
Permit Status: Expired
Permit Description: REPLACE:EVAP COOLER WITH A/C CONDENSER ON ROOF, REPLACE:FURNACE INSIDE BUILDING T09CM03052
Start Date Submittal Complete Date Status  
11/19/2009 OTHER 11/19/2009 ACTIVE Review Details

Outstanding Activity Conditions

Permit Number - T09CM03052
Permit Status: Expired
Permit Description: REPLACE:EVAP COOLER WITH A/C CONDENSER ON ROOF, REPLACE:FURNACE INSIDE BUILDING T09CM03052
Total Outstanding Activity Conditions - 3
Date Name
11/19/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
11/19/2009 SPECIAL INSPECTION FORMS AND REPORTS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY.
11/19/2009 SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED.

Outstanding Inspections

Permit Status: Expired
Permit Number: T09CM03052
Permite Description: REPLACE:EVAP COOLER WITH A/C CONDENSER ON ROOF, REPLACE:FURNACE INSIDE BUILDING T09CM03052
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
MECHANICAL - FINAL N/A Not Inspected
11/20/2009 MECHANICAL - INTERMEDIATE N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TERMINATE CONDENSATE TO AN APPROVED LOCATION
2) USE PURPLE PRIMER ON ALL PVC FITTINGS PRIOR TO GLUE
3) PROVIDE A TRAP ON CONDENSATE DRAIN
4) PROVIDE A SECONDARY OVERFLOW SENSOR
5) INSULATE ALL METAL DUCTING ABOVE FURNACE
6) PROVIDE A VENT FOR FURNACE AND WATER HEATER
7) DO NOT HAVE PVC WITHIN 6" OF SINGLE WALL VENT
8) GAS FLEX CONNECTOR CANNOT PASS THRU THE CABINET OF FURNACE
9) PROVIDE A SEDIMENT TRAP IN GAS LINE TO FURNACE
10) PROVIDE PROTECTION ON REFER LINES AT CONNECTION TO EVAP COIL
11) PROVIDE A ROMEX CONNECTOR AT FURNACE CORD
12) CORRECTIONS ARE TOO NUMEROUS TO LIST
13) HAVE MECHANICAL CONTRACTOR ON JOB SITE AT NEXT INSPECTION
14) DO NOT USE MC CABLE EXPOSED ON ROOF
15) PROVIDE ROOF JACKS AT ALL ROOF PENETRATIONS
16) LIST MAY NOT BE COMPLETE