Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
11/10/2009
Applicant:
N/A
Description:
SFR:BLUEMODEL2 T09-M0035
Contractors:
  • BLUE GRANITE CONSTRUCTION L L C

Permit Reviews

Permit Number - T09CM02973
Permit Status: C of o
Permit Description: SFR:BLUEMODEL2 T09-M0035
Start Date Submittal Complete Date Status  
11/10/2009 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 11/10/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09CM02973
Permit Status: C of o
Permit Description: SFR:BLUEMODEL2 T09-M0035
Total Outstanding Activity Conditions - 1
Date Name
11/10/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T09CM02973
Permit Description: SFR:BLUEMODEL2 T09-M0035
Total Completed Inspections - 25
Date Description Inspector Results Comments
12/22/2009 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :*
1) RECALL FOR PRE-SLAB
2) POST ADDRESS
01/05/2010 ELECTRIC - UFER GDABBS Approved IVRS - Inspection :*
01/05/2010 BUILDING PRE-SLAB GDABBS Approved IVRS - Inspection :*
01/05/2010 EXCAVATION/LAYOUT REBAR & ZON GDABBS Approved IVRS - Inspection :*
02/17/2010 ROOF NAILING EDURAZO Approved IVRS - Inspection :*
04/20/2010 EXT METAL CLIPS/EXT SHEATHING RCAMACHO Approved IVRS - Inspection :*
05/05/2010 PLUMBING - SEWER HCS CONNECT DQUINN Approved IVRS - Inspection :*
05/05/2010 PLUMBING - YARD WTR LINE/TEST DQUINN Approved IVRS - Inspection :*
06/30/2010 U VALUE FOR WINDOW DQUINN Approved IVRS - Inspection :*
06/30/2010 STUCCO MESH DQUINN Approved IVRS - Inspection :*
09/28/2010 MECHANICAL - INTERMEDIATE RCAMACHO Approved IVRS - Inspection :*
09/28/2010 PLUMBING - GAS PRESSURE TEST RCAMACHO Approved IVRS - Inspection :*
09/28/2010 ELECTRIC - INTERMEDIATE RCAMACHO Approved IVRS - Inspection :*
10/06/2010 PLUMBING - INTERMEDIATE RCAMACHO Approved IVRS - Inspection :*
10/06/2010 FRAMING RCAMACHO Approved IVRS - Inspection :*
11/09/2010 ELECTRIC - UNDERGROUND DWALKER Approved IVRS - Inspection :*
11/09/2010 SHEET ROCK NAILING DWALKER Approved IVRS - Inspection :*
04/19/2011 ELECTRIC - TEMPORARY SERVICE DQUINN Approved IVRS - Inspection :*
04/19/2011 ELECTRIC - CABLE DROP DQUINN Approved IVRS - Inspection :*
04/20/2011 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER D. QUINN
10/18/2011 BUILDING - FINAL DQUINN Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED TANKLESS CONDENSATE
2) NEED CLOSET LIGHT COVERS
10/18/2011 MECHANICAL - FINAL DQUINN Approved IVRS - Inspection :
See detailed listing on site.| 999*
10/18/2011 PLUMBING - FINAL DQUINN Approved IVRS - Inspection :*
10/18/2011 ELECTRIC - FINAL DQUINN Approved IVRS - Inspection :
See detailed listing on site.| 999*
07/09/2012 BUILDING - PROGRESS DQUINN Approved

Documents

File Name Document Type  
None CERT OF OCC VIEW
None CONSTRPLANS VIEW
None DOCUMENTS VIEW