Inspection History: FRAMING
Permit Number - T09CM02973
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/06/2010 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/01/2010 | FRAMING | Partial Approval | IVRS - Inspection :* 1) UPSTAIRS NOTES #1 & 3 |
|
| 09/28/2010 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* DOWNSTAIRS: 1) 5/8" AB'S 32" ON CENTER ALL SW3 SHEAR WALLS 1/2" ALL SW2 2) PROVIDE 12" CLEARANCE ALL PEX FROM CANS 3) BLOCK REGISTER BOOTS 3 SIDES 4) SECURE ALL ROMEX 8" FROM BOXES 5) COMPLY WITH STAIR DETAIL 3/A1 6) COMPLY WITH HOME ? BLOCKING BATH 7) RELOCATE OUTLET BREAKFAST NOOK PER PLAN UPSTAIRS: 1) NAIL PROTECT PLUMBING THROUGHOUT 2) OVERKNOTCHED STUD MASTER BATH 3) COMPLY WITH KEY NOTE 15 6" WALL MISSING CS AT SW2 MASTER BATH |
|
| 08/17/2010 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |