Permit: T09CM02965
Permit Details
Status:
Expired
Type:
SINGLE FAMILY COMPLIANCE
Address:
1602 W BUCKEYE LN
Address NEW:
1602 W BUCKEYE LN
Apply Date:
11/09/2009
Applicant:
N/A
Description:
GENERAL REPAIR:ELECTRICAL CIRCUITS/DRYWALL & INSTALL:WATER HEATER T09DV05157
Contractors:
- J E B ELECTRIC INC ,
Permit Reviews
Permit Number - T09CM02965
Permit Status: Expired
Permit Description: GENERAL REPAIR:ELECTRICAL CIRCUITS/DRYWALL & INSTALL:WATER HEATER T09DV05157
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/09/2009 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 12/22/2009 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09CM02965
Permit Status: Expired
Permit Description: GENERAL REPAIR:ELECTRICAL CIRCUITS/DRYWALL & INSTALL:WATER HEATER T09DV05157
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/09/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T09CM02965
Permite Description: GENERAL REPAIR:ELECTRICAL CIRCUITS/DRYWALL & INSTALL:WATER HEATER T09DV05157
Total Outstanding Inspections - 8
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| BUILDING - FINAL | N/A | Not Inspected | ||
| ELECTRIC - PROGRESS | N/A | Not Inspected | ||
| ELECTRIC - FINAL | N/A | Not Inspected | ||
| 02/04/2010 | SHEET ROCK NAILING | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MAIN DISCONNECT SERVICE OVER 6 CIRCUITS 2) SEAL PENETRATIONS PANEL 3) IDENTIFY ALL CIRCUITS 4) WATER HEATER EXTEND TPR VALVE 6"-24" FROM GROUND 3/4" COPPER CVPC OR GALV. DRIP LEG GAS LINE COLD WATER SHUT OFF. PROVIDE CLEARANCE B-VENT FROM COMBUSTIBLES 5) REPLACE ALL EXTERIOR PLASTIC SUPPLY LINES 6) PROTECT ROMEX UNDER 7' STORAGE-SECURE ROMEX 8" FROM BOX 7) GFCI PROTECT KITCHEN OUTLETS 8) RELOCATE SMOKE ALARMS MINIMUM 36" FORCED AIR REGISTERS 9) ALL 2 WIRE WITH GROUND OUTLETS MUST TEST OR REPLACE WITH 2 WIRE OUTLETS OR GFCI PROTECT |
| 02/04/2010 | ELECTRIC - INTERMEDIATE | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 02/04/2010 | PLUMBING - INTERMEDIATE | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 10/14/2010 | BUILDING - PROGRESS | N/A | Not ready for Inspection | IVRS - Inspection :* |
| 10/14/2010 | PLUMBING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* |