Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY COMPLIANCE
Address NEW:
1602 W BUCKEYE LN
Apply Date:
11/09/2009
Applicant:
N/A
Description:
GENERAL REPAIR:ELECTRICAL CIRCUITS/DRYWALL & INSTALL:WATER HEATER T09DV05157
Contractors:
  • J E B ELECTRIC INC ,

Permit Reviews

Permit Number - T09CM02965
Permit Status: Expired
Permit Description: GENERAL REPAIR:ELECTRICAL CIRCUITS/DRYWALL & INSTALL:WATER HEATER T09DV05157
Start Date Submittal Complete Date Status  
11/09/2009 RESIDENTIAL BLDG/ZONING-WALKTHRU 12/22/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09CM02965
Permit Status: Expired
Permit Description: GENERAL REPAIR:ELECTRICAL CIRCUITS/DRYWALL & INSTALL:WATER HEATER T09DV05157
Total Outstanding Activity Conditions - 1
Date Name
11/09/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T09CM02965
Permite Description: GENERAL REPAIR:ELECTRICAL CIRCUITS/DRYWALL & INSTALL:WATER HEATER T09DV05157
Total Outstanding Inspections - 8
Last Inspection Date Description Inspector Results Comments
BUILDING - FINAL N/A Not Inspected
ELECTRIC - PROGRESS N/A Not Inspected
ELECTRIC - FINAL N/A Not Inspected
02/04/2010 SHEET ROCK NAILING N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MAIN DISCONNECT SERVICE OVER 6 CIRCUITS
2) SEAL PENETRATIONS PANEL
3) IDENTIFY ALL CIRCUITS
4) WATER HEATER EXTEND TPR VALVE 6"-24" FROM GROUND 3/4" COPPER CVPC OR GALV. DRIP LEG GAS LINE COLD WATER SHUT OFF. PROVIDE CLEARANCE B-VENT FROM COMBUSTIBLES
5) REPLACE ALL EXTERIOR PLASTIC SUPPLY LINES
6) PROTECT ROMEX UNDER 7' STORAGE-SECURE ROMEX 8" FROM BOX
7) GFCI PROTECT KITCHEN OUTLETS
8) RELOCATE SMOKE ALARMS MINIMUM 36" FORCED AIR REGISTERS
9) ALL 2 WIRE WITH GROUND OUTLETS MUST TEST OR REPLACE WITH 2 WIRE OUTLETS OR GFCI PROTECT
02/04/2010 ELECTRIC - INTERMEDIATE N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
02/04/2010 PLUMBING - INTERMEDIATE N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
10/14/2010 BUILDING - PROGRESS N/A Not ready for Inspection IVRS - Inspection :*
10/14/2010 PLUMBING - FINAL N/A Not ready for Inspection IVRS - Inspection :*

Documents

File Name Document Type  
None CONSTRPLANS VIEW
None DOCUMENTS VIEW