Inspection History Details
Inspection Status: Denied
Inspection History: SHEET ROCK NAILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/04/2010 | SHEET ROCK NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MAIN DISCONNECT SERVICE OVER 6 CIRCUITS 2) SEAL PENETRATIONS PANEL 3) IDENTIFY ALL CIRCUITS 4) WATER HEATER EXTEND TPR VALVE 6"-24" FROM GROUND 3/4" COPPER CVPC OR GALV. DRIP LEG GAS LINE COLD WATER SHUT OFF. PROVIDE CLEARANCE B-VENT FROM COMBUSTIBLES 5) REPLACE ALL EXTERIOR PLASTIC SUPPLY LINES 6) PROTECT ROMEX UNDER 7' STORAGE-SECURE ROMEX 8" FROM BOX 7) GFCI PROTECT KITCHEN OUTLETS 8) RELOCATE SMOKE ALARMS MINIMUM 36" FORCED AIR REGISTERS 9) ALL 2 WIRE WITH GROUND OUTLETS MUST TEST OR REPLACE WITH 2 WIRE OUTLETS OR GFCI PROTECT |