Permit: T09CM02965

Parcel: 106120190


Addresses:

1602 W BUCKEYE LN

Inspection Status: Denied

Inspection History: SHEET ROCK NAILING

Date Description Inspector Results Comments
02/04/2010 SHEET ROCK NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MAIN DISCONNECT SERVICE OVER 6 CIRCUITS
2) SEAL PENETRATIONS PANEL
3) IDENTIFY ALL CIRCUITS
4) WATER HEATER EXTEND TPR VALVE 6"-24" FROM GROUND 3/4" COPPER CVPC OR GALV. DRIP LEG GAS LINE COLD WATER SHUT OFF. PROVIDE CLEARANCE B-VENT FROM COMBUSTIBLES
5) REPLACE ALL EXTERIOR PLASTIC SUPPLY LINES
6) PROTECT ROMEX UNDER 7' STORAGE-SECURE ROMEX 8" FROM BOX
7) GFCI PROTECT KITCHEN OUTLETS
8) RELOCATE SMOKE ALARMS MINIMUM 36" FORCED AIR REGISTERS
9) ALL 2 WIRE WITH GROUND OUTLETS MUST TEST OR REPLACE WITH 2 WIRE OUTLETS OR GFCI PROTECT