Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY ADDITION
Apply Date:
10/26/2009
Applicant:
N/A
Description:
ADD: PATIO COVER, OUTDOOR LIGHT

Outstanding Activity Conditions

Permit Number - T09CM02845
Permit Status: Expired
Permit Description: ADD: PATIO COVER, OUTDOOR LIGHT
Total Outstanding Activity Conditions - 1
Date Name
10/26/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T09CM02845
Permite Description: ADD: PATIO COVER, OUTDOOR LIGHT
Total Outstanding Inspections - 7
Last Inspection Date Description Inspector Results Comments
STUCCO MESH N/A Not Inspected
ELECTRIC - FINAL N/A Not Inspected
OUTDOOR LIGHTING FINAL N/A Not Inspected
02/12/2010 BUILDING - FINAL N/A Not ready for Inspection IVRS - Inspection :*
1) UNABLE TO LOCATE PLANS AND PERMIT
2) NEED TO RESEARCH, BARRIER REQUIREMENT, THIS POOL DATES, WAS BARRIER REQUIRED IN CITY AMENDMENTS WHEN POOL WAS BUILT ?
3) HEADER FOR DBL FRENCH DOORS WAS COVERED, NO INSPECTION, HOMEOWNER STATES DBL 2 X 10 WAS INSTALLED
4) USE CORRECT FAN BOX AND A GREEN GRD. SCREW
12/16/2009 ROOF NAILING N/A Partial Approval IVRS - Inspection :*
1) FROM LAST INSPECTION, ROOF NAILING TO LEDGER THAT TIES THE STRUCTURE TO THE LEDGER, OR ALL YOU HAVE ARE 10D TECOS, I SEE THE SCREWS AT A TOE NAIL HOW LONG ARE THEY ?
2) YOU NEED TO TREAT 2 X 4 PLATES WITH A WOOD PRE-SERVATIVE AT COLS SHOULD HAVE USED TREATED LUMBER
3) PATIO DOOR WAS THAT INSTALLED RECENTLY ? IF SO NOT ON PLAN NEED HEADER
4) GRD SCREW AT METAL BOX CEILING-BOND BOX
12/16/2009 FRAMING N/A Partial Approval IVRS - Inspection :*
12/16/2009 ELECTRIC - INTERMEDIATE N/A Partial Approval IVRS - Inspection :*

Completed Inspections

Permit Status: Expired
Permit Number: T09CM02845
Permit Description: ADD: PATIO COVER, OUTDOOR LIGHT
Total Completed Inspections - 1
Date Description Inspector Results Comments
12/01/2009 EXCAVATION/LAYOUT REBAR & ZON RFREIDIN Approved IVRS - Inspection :*
1) IF YOU DON'T NAIL OSB ROOF DECK TO LEDGER USE AT LEDGER (2) SCREWS PER SIDE OF HANGER (NOT SHEETROCK SCREWS)
2) ROOF DECK TO LEDGER IS THE CONNECTION HOLDING RAFTER TO THE WALL

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW